Product Details | MOTOR STARTER

6110-00-134-9093 A device primarily designed to control the supply circuit(s) of a motor in order to accelerate the motor from rest to normal speed. Includes manual starters with overload protection and manual, automatic or semiautomatic starters consisting of combinations of items such as relays, resistors, switches, circuit breakers, etc. Excludes RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (as modified) and RELAY (as modified). For devices, which in addition to starting and stopping, reverse, select and/or regulate the speed of a motor, see CONTROLLER (as modified).

Part Alternates: 8536SCA4120VB14, 8536SCA4-120VB14, 8536SCA4V02SY92B14, 6110-00-134-9093, 00-134-9093, 6110001349093, 001349093

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 19 AUG 1972 00-134-9093

Cross Reference | NSN 6110-00-134-9093

Part Number Cage Code Manufacturer
8536SCA4-120VB14 51918 SCHNEIDER ELECTRIC USA, INC.
8536SCA4V02SY92(B14) 51920 SQUARE D CO COLUMBIA MFG PLANT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-00-134-9093

Technical Data | NSN 6110-00-134-9093

Characteristic Specifications
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN DESIGNED PER NEMA STD
SIZE DESIGNATOR 1
OPERATING VOLTAGE CHARACTERISTIC FULL
AC VOLTAGE RATING 575.0 VOLTS MAXIMUM
FREQUENCY RATING 60.0 HERTZ NOMINAL
PHASE THREE
HORSEPOWER RATING 7.500 AND 10.000
CONTROL TYPE REMOTE
ACTUATION METHOD MAGNETIC
ACTUATOR VOLTAGE 120.0 AC
FREQUENCY IN HERTZ 60.0
CIRCUIT PROTECTION FUSE NOT PROVIDED
PERFORMANCE TYPE SEMIAUTOMATIC
LOAD PROTECTION TYPE OVERLOAD
DUTY CYCLE CONTINUOUS
AMBIENT TEMP NOT RATED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION INDUSTRIAL USE-NEMA TYPE 12
INCLOSURE FEATURE DRIPPROOF AND DUSTPROOF
OVERALL WIDTH 6.375 INCHES NOMINAL
OVERALL LENGTH 12.750 INCHES NOMINAL
OVERALL HEIGHT 7.375 INCHES NOMINAL
MOUNTING CONFIGURATION FOUR 5/16 IN. DIA MTG HOLES ON 12 IN. BY 4-1/4IN. MTG CENTERS
SWITCH FUNCTIONAL POSITIONS RESET
ACCESSORY NOT INCLUDED
SPECIAL FEATURES WITH B14 HEATERS
III USAGE DESIGN LINE STARTER
MANUFACTURERS CODE 51920
DESIGN CONTROL REFERENCE 8536SCA4V02SY92(B14)

Restrictions/Controls & Freight Information | NSN 6110-00-134-9093

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 130395 STARTERS OR STARTER MOTORS
Less than car load rating
Less than truck load rating Q 70.0
Water commodity Code 593 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6110-00-134-9093

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeSXSX:AF SICA RESIDUAL MMAC-OC-ALC
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesLLOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each