Product Details | GENERATOR CONTROL

6110-00-165-3848 A device which determines the mode of operation of a generator. See also PANEL, POWER DISTRIBUTION.

Part Alternates: 14609003, 14-60900-3, 6110-00-165-3848, 00-165-3848, 6110001653848, 001653848

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 10 OCT 1971 00-165-3848

Cross Reference | NSN 6110-00-165-3848

Part Number Cage Code Manufacturer
14-60900-3 0JRC1 NORTHROP GRUMMAN TECHNICAL SERVICES, INC.
14-60900-3 76823 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-00-165-3848

Technical Data | NSN 6110-00-165-3848

Characteristic Specifications
POWER SOURCE EXTERNAL
MAXIMUM VOLTAGE RATING IN VOLTS 187.0 AC OR 205.0 AC AND 18.0 DC OR 32.0 DC
FREQUENCY IN HERTZ 320.0 OR 480.0
PHASE THREE
TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE
TERMINAL LOCATION FRONT
CONNECTOR MANUFACTURER PART NUMBER PTO8CP16-26S
CONNECTOR MANUFACTURER CODE 19315
CASE MATERIAL STEEL
INCLOSURE TYPE HERMETICALLY SEALED
MAXIMUM OVERALL LENGTH 7.800 INCHES
MAXIMUM OVERALL WIDTH 6.300 INCHES
MAXIMUM OVERALL HEIGHT 3.700 INCHES
OPERATING TEMP RANGE -65.0 TO 248.0 DEG FAHRENHEIT
MOUNTING METHOD BRACKET
MANUFACTURERS CODE 76823
DESIGN CONTROL REFERENCE 14-60900-3

Restrictions/Controls & Freight Information | NSN 6110-00-165-3848

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061480 CONTROLLERS/PARTS NOI O/T PLASTIC
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 590 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable