NSN 6110-00-186-2537 6002608, 00-186-2537, 001862537
Product Details | POWER DISTRIBUTION PANEL
6110-00-186-2537 A panel designed for connecting, disconnecting and protecting power line feeders and/or direct control of specific electric devices such as lights, motors, electronic equipment, etc. See also FUSE BOX; SWITCH BOX; DISTRIBUTION BOX; and PANEL, POWER BUS, CIRCUIT BREAKER.
Part Alternates: 6002608, 6110-00-186-2537, 00-186-2537, 6110001862537, 001862537
Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | 09 MAR 1973 | 00-186-2537 | 02794 ( PANEL, POWER DISTRIBUTION ) |
Cross Reference | NSN 6110-00-186-2537
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 6002608 | 80091 | NAVAL FACILITIES ENGINEERING COMMAND |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6110-00-186-2537
Related Products | NSN 6110-00-186-2537
Technical Data | NSN 6110-00-186-2537
| Characteristic | Specifications |
|---|---|
| INCLOSURE FEATURE | WATERPROOF |
| PANEL QUANTITY | 1 |
| ELECTRICAL INPUT QUANTITY | 1 |
| INPUT VOLTAGE RATING | 480.0 AC VOLTS MAXIMUM |
| INPUT FREQUENCY IN HERTZ | 60.0 |
| INPUT PHASE | THREE |
| ELECTRICAL OUTPUT QUANTITY | 7 |
| OUTPUT VOLTAGE RATING | 120.0 AC VOLTS MINIMUM AND 208.0 AC VOLTS MAXIMUM |
| OUTPUT FREQUENCY RATING | 60 HERTZ |
| PHASE | THREE |
| OVERALL HEIGHT | 40.000 INCHES MAXIMUM |
| OVERALL WIDTH | 36.000 INCHES MAXIMUM |
| OVERALL LENGTH | 72.000 INCHES MAXIMUM |
| PANEL MATERIAL | ALUMINUM |
| MOUNTING METHOD | FLOOR |
| SPECIAL FEATURES | PORTABLE ASSEMBLED UNIT ARRANGED SO IT CAN BE LIFTED BY A FORK LIFT,PROVIDED W/TOW BAR AND SLED,CONSISTS OF2 3-POLE CIRCUIT BREAKERS,225 AMP,480V,3 3-POLE CIRCUIT BREAKERS,100 AMP,480V,1 3-POLE CIRCUIT BREAKER,70AMP,480V,4 3-POLE CIRCUIT BREAKERS,30 AMP,208V,2 2-POLE CIRCUIT BREAKERS,50 AMP,208V,1 3-POLE CIRCUIT BREAKER,100 AMP,208V,8 GROUND FAULT CIRCUIT BREAKERS,20 AMP,120V CONNECTED TO NEMA RECEPTACLES,3 10KVA,480-120V 10 TRANSFORMERS CONNECTED 480-208V/120 FOR 30KVA CAPACITY,1 GROUND LUG CONNECTOR |
| NONDEFINITIVE SPEC/STD DATA | II TYPE AND 2 CLASS |
| MANUFACTURERS CODE | 80091 |
| DESIGN CONTROL REFERENCE | 6002608 |
Restrictions/Controls & Freight Information | NSN 6110-00-186-2537
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
| Less than car load rating | P | 77.5 |
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | JS | Naval ICP Mechanicsburg, PA 17055-0788 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6110-00-186-2537
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 2C | Major construction and civil engineering equipment Civil Engineer Support Office 2D |
| Issue Repair, or Requisition | AH | Submit/refer requisitions to CESO (Civil Engineer Support Office) CBC Port Hueneme. |
| Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
| Source of Supply | R41 | Naval Facilities Expenditionary Logistics Center Code N42 Bldg 1000 23rd Ave Port Hueneme, CA 93043 |
| Agency | DN | Department of the Navy |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | V | 2C Cog CEEI Material (major end item) |
| Acquisition Advice Codes | A | SERVICE/AGENCY-REGULATED (Service/Agency use only.) # Issue, transfer or shipment is controlled by authorities above the ICP level to assure proper and equitable distribution. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |