Product Details | MOTOR STARTER

6110-00-209-1842 A device primarily designed to control the supply circuit(s) of a motor in order to accelerate the motor from rest to normal speed. Includes manual starters with overload protection and manual, automatic or semiautomatic starters consisting of combinations of items such as relays, resistors, switches, circuit breakers, etc. Excludes RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (as modified) and RELAY (as modified). For devices, which in addition to starting and stopping, reverse, select and/or regulate the speed of a motor, see CONTROLLER (as modified).

Part Alternates: 8536SCW12240VC0IL, 8536SCW12-240VC0IL, 8536SCW12V03, 6110-00-209-1842, 00-209-1842, 6110002091842, 002091842

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 20 APR 1973 00-209-1842

Cross Reference | NSN 6110-00-209-1842

Part Number Cage Code Manufacturer
8536SCW12-240VC0IL 56365 SCHNEIDER ELECTRIC USA, INC. DBA SCHNEIDER ELECTRIC
8536SCW12V03 51920 SQUARE D CO COLUMBIA MFG PLANT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-00-209-1842

Technical Data | NSN 6110-00-209-1842

Characteristic Specifications
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN DESIGNED PER NEMA STD
SIZE DESIGNATOR 1P
OPERATING VOLTAGE CHARACTERISTIC FULL
AC VOLTAGE RATING 600.0 VOLTS MAXIMUM
FREQUENCY RATING 50.0 HERTZ NOMINAL AND 60.0 HERTZ NOMINAL
PHASE SINGLE
HORSEPOWER RATING 3.000 AND 5.000
CONTROL TYPE LOCAL
ACTUATION METHOD MAGNETIC
ACTUATOR VOLTAGE 240.0 AC
FREQUENCY IN HERTZ 50.0 AND 60.0
CIRCUIT PROTECTION FUSE NOT PROVIDED
PERFORMANCE TYPE SEMIAUTOMATIC
LOAD PROTECTION TYPE OVERLOAD
DUTY CYCLE CONTINUOUS
AMBIENT TEMP NOT RATED
REVERSIBLE FEATURE NOT INCLUDED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION WATERTIGHT-NEMA TYPE 4
INCLOSURE FEATURE DUSTPROOF AND WATERTIGHT
OVERALL WIDTH ANY ACCEPTABLE
OVERALL LENGTH ANY ACCEPTABLE
OVERALL HEIGHT ANY ACCEPTABLE
MOUNTING CONFIGURATION ANY ACCEPTABLE
SWITCH FUNCTIONAL POSITIONS RESET AND START AND STOP
ACCESSORY NOT INCLUDED
III USAGE DESIGN LINE STARTER
MANUFACTURERS CODE 56365
DESIGN CONTROL REFERENCE 8536SCW12-240VC0IL

Restrictions/Controls & Freight Information | NSN 6110-00-209-1842

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 130395 STARTERS OR STARTER MOTORS
Less than car load rating
Less than truck load rating Q 70.0
Water commodity Code 593 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6110-00-209-1842

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Fund CodeLPItems initially authorized for local purchase.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeSXSX:AF SICA RESIDUAL MMAC-OC-ALC
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesLLOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each