Product Details | POWER DISTRIBUTION PANEL

6110-00-213-8078 A panel designed for connecting, disconnecting and protecting power line feeders and/or direct control of specific electric devices such as lights, motors, electronic equipment, etc. See also FUSE BOX; SWITCH BOX; DISTRIBUTION BOX; and PANEL, POWER BUS, CIRCUIT BREAKER.

Part Alternates: MILP29183, MIL-P-29183, 6002625, 6110-00-213-8078, 00-213-8078, 6110002138078, 002138078

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 25 APR 1973 00-213-8078

Cross Reference | NSN 6110-00-213-8078

Part Number Cage Code Manufacturer
6002625 80091 NAVAL FACILITIES ENGINEERING COMMAND
MIL-P-29183 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-00-213-8078

Technical Data | NSN 6110-00-213-8078

Characteristic Specifications
INCLOSURE FEATURE WATERPROOF
PANEL QUANTITY 1
ELECTRICAL INPUT QUANTITY 1
INPUT VOLTAGE RATING 120.0 AC VOLTS MINIMUM AND 480.0 AC VOLTS MAXIMUM
INPUT FREQUENCY IN HERTZ 60.0
INPUT PHASE THREE
ELECTRICAL OUTPUT QUANTITY 6
OUTPUT VOLTAGE RATING 120.0 AC VOLTS MINIMUM AND 480.0 AC VOLTS MAXIMUM
OUTPUT FREQUENCY RATING 60 HERTZ
PHASE THREE
OVERALL HEIGHT 36.000 INCHES MAXIMUM
OVERALL WIDTH 36.000 INCHES MAXIMUM
OVERALL LENGTH 84.000 INCHES MAXIMUM
PANEL MATERIAL ALUMINUM
MOUNTING METHOD FLOOR
SPECIAL FEATURES PANELBOARD ARRANGED IN HORIZONTAL CONFIGURATION W/ENCLOSURE BACK AS BOTTOM SIDE AND INCLUDE HINGED COVER ON TOPSIDE,WEATHERPROOFED,CIRCUIT BREAKERS TO BE 3-POLE W/INTERRUPTING RATINGSAT 480V AC IN ACCORDANCE W/FED-SPEC W-C-375A AMEND 4,BE CLASSES AND TRIP RATINGS CONNECTED TO 3-PHASE,1200AMPERE BUS BAR,CL 2F 100 AMP TRIP-2 EA,CL 3B 225 AMP TRIP-6 EA,CL 4B 400 AMP NON-AUTOMATIC TRIP-4 EA,CONDUIT BUSHINGS TO BE TWO-PIECE INSULATING CONFORMING TO TYPE 3,CL 1,KIND R,FED-SPEC W-C-408B IN SIZES AND QUANTITIES,2 IN-2 EA F/10 AMP CIRCUIT BREAKER CONDUCTOR,3 IN-6 EA F/225 AMP CIRCUIT BREAKER CONDUCTOR,4 IN-4 EA F/400 AMP CIRCUITBREAKER CONDUCTOR,CONDUIT BUSHINGS INSTALLED IN ENCLOSURE BOTTOM SIDE IN RELATIVE LOCATION TO CIRCUIT BREAKERS THEY ARE TO BE UTILIZED,1 GROUND TERMINAL W/SOLDERLESS LUG,SOLDERLESS LUG SHALL BE COMPATIBLE W/ALUMINUM AND COPPER AND HAVE THE CAPACITY F/1 NO. 6-AWG COPPER CONDUCTOR,CONFORMS TO PORTA-POWER PAC INC,DWG NO. 105100 OR EQUAL
SPECIFICATION/STANDARD DATA 81349-MIL-P-29183 GOVERNMENT SPECIFICATION
NONDEFINITIVE SPEC/STD DATA III TYPE AND 3 CLASS
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS AS MODIFIED BY CONFIGURATION OF PANELBOARD
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-P-29183
MANUFACTURERS CODE 80091
DESIGN CONTROL REFERENCE 6002625

Restrictions/Controls & Freight Information | NSN 6110-00-213-8078

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code JS Naval ICP
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6110-00-213-8078

Category Code Description
Cognizance Codes2CMajor construction and civil engineering equipment
Civil Engineer Support Office 2D
Issue Repair, or RequisitionAHSubmit/refer requisitions to CESO (Civil Engineer Support Office) CBC Port Hueneme.
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplyR41Naval Facilities Expenditionary Logistics Center
Code N42
Bldg 1000 23rd Ave
Port Hueneme, CA 93043
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityV2C Cog CEEI Material (major end item)
Acquisition Advice CodesASERVICE/AGENCY-REGULATED (Service/Agency use only.) # Issue, transfer or shipment is controlled by authorities above the ICP level to assure proper and equitable distribution. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each