Product Details | MOTOR STARTER

6110-00-233-6626 A device primarily designed to control the supply circuit(s) of a motor in order to accelerate the motor from rest to normal speed. Includes manual starters with overload protection and manual, automatic or semiautomatic starters consisting of combinations of items such as relays, resistors, switches, circuit breakers, etc. Excludes RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (as modified) and RELAY (as modified). For devices, which in addition to starting and stopping, reverse, select and/or regulate the speed of a motor, see CONTROLLER (as modified).

Part Alternates: 346318PC1, 392200GP191, 3PHL12005, 3PHL1200-5, 6110-00-233-6626, 00-233-6626, 6110002336626, 002336626

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 01 JAN 1963 00-233-6626

Demand History | NSN 6110-00-233-6626

Part Number Request Date QTY Origin
6110-00-233-6626 2015-01-13 4 Taiwan
6110-00-233-6626 2014-11-307 4 Taiwan

Cross Reference | NSN 6110-00-233-6626

Part Number Cage Code Manufacturer
346318PC1 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
392200GP191 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
3PHL1200-5 1R4E4 DEVLIEG BULLARD II INC.
3PHL1200-5 42337 ACME-CLEVELAND CORP NATIONAL ACME DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-00-233-6626

Technical Data | NSN 6110-00-233-6626

Characteristic Specifications
OPERATING VOLTAGE CHARACTERISTIC FULL
DC VOLTAGE RATING 230.0 VOLTS NOMINAL
DIRECT CURRENT RATING IN AMPS 1.60
HORSEPOWER RATING 0.333
CONTROL TYPE LOCAL
ACTUATION METHOD MANUAL
PERFORMANCE TYPE MANUAL
LOAD PROTECTION TYPE OVERLOAD
DUTY CYCLE CONTINUOUS
AMBIENT TEMP 50.0 DEG CELSIUS
SPEED ADJUSTMENTS SINGLE SPEED
REVERSIBLE FEATURE NOT INCLUDED
INCLOSURE FEATURE WATERTIGHT
OVERALL WIDTH 4.250 INCHES NOMINAL
OVERALL LENGTH 7.875 INCHES NOMINAL
OVERALL HEIGHT 4.344 INCHES NOMINAL
MOUNTING CONFIGURATION FOUR 13/32 IN. DIA MTG HOLES ON 3-1/4 IN. BY 6-27/32 IN. MTG CENTERS
SWITCH FUNCTIONAL POSITIONS EMERGENCY AND START AND STOP
ACCESSORY INCLUDED
III USAGE DESIGN U/W HEATERS

Restrictions/Controls & Freight Information | NSN 6110-00-233-6626

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 062120 GENERATORS/MOTORS/PARTS NOI
Less than car load rating Q 70
Less than truck load rating W Rating Variable
Water commodity Code 593 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable