Product Details | POWER DISTRIBUTION PANEL

6110-00-945-8944 A panel designed for connecting, disconnecting and protecting power line feeders and/or direct control of specific electric devices such as lights, motors, electronic equipment, etc. See also FUSE BOX; SWITCH BOX; DISTRIBUTION BOX; and PANEL, POWER BUS, CIRCUIT BREAKER.

Part Alternates: SB2400TRC97, 8354634501, 8354634-501, 6110-00-945-8944, 00-945-8944, 6110009458944, 009458944

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 14 MAR 1966 00-945-8944

Cross Reference | NSN 6110-00-945-8944

Part Number Cage Code Manufacturer
8354634-501 01238 COMMUNICATIONS AND POWER INDUSTRIES SOLID STATE PRODUCTS DIV
8354634-501 11447 L-3 COMMUNICATIONS CORPORATION DBA COMMUNICATION SYSTEMS - EAST
8354634-501 21530 SPENCER INDUSTRIES INC
8354634-501 31791 3DBM CO INC
8354634-501 49671 LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS
SB2400TRC97 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-00-945-8944

Technical Data | NSN 6110-00-945-8944

Characteristic Specifications
PANEL QUANTITY 1
ELECTRICAL INPUT QUANTITY 1
INPUT VOLTAGE RATING 208.0 AC VOLTS NOMINAL 120.0 AC VOLTS NOMINAL
WATTAGE RATING IN WATTS 9340.0
INPUT FREQUENCY IN HERTZ 400.0
INPUT PHASE THREE
INPUT NEUTRAL PROVIDED
ELECTRICAL OUTPUT QUANTITY 81
OUTPUT VOLTAGE RATING 120.0 AC VOLTS MINIMUM AND 208.0 AC VOLTS MAXIMUM
OUTPUT WATTAGE RATING IN WATTS 225.0 1065.0 720.0 5750.0 85.0 150.0 300.0 480.0 120.0
OUTPUT FREQUENCY RATING 400 HERTZ
PHASE THREE THREE THREE THREE SINGLE SINGLE SINGLE SINGLE SINGLE
OUTPUT NEUTRAL PROVIDED
OVERALL HEIGHT 13.910 INCHES NOMINAL
OVERALL WIDTH 19.000 INCHES NOMINAL
OVERALL DEPTH 4.500 INCHES NOMINAL
PANEL MATERIAL ALUMINUM
SURFACE TREATMENT ENAMEL
MOUNTING METHOD RACK
SHOCK ABSORBENT RATING PER MIL-C-16400E

Restrictions/Controls & Freight Information | NSN 6110-00-945-8944

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061360 COILS/YOKES FOCUS/DEFLECTION TV
Less than car load rating M 85
Less than truck load rating M 85.0
Water commodity Code 658 unknown
Originating Activity Code SG 403 SCMS/GUED
5215 Thurlow St, Suite 5, Bldg 70C
Wright-Patterson AFB OH 45433
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable