NSN 6110-01-184-5560 77D609501G4, 77E300317G4, 01-184-5560
Product Details | VOLTAGE REGULATOR
6110-01-184-5560 A component within a single inclosure or provided with a single mounting specifically designed to control automatically the voltage output of an electrical system within certain required limits, regardless of variations of the effective load or of input voltages within a specific range. Does not include items in which regulation is accomplished solely by transformer action. See also REGULATOR SET, VOLTAGE. Excludes REGULATOR, ENGINE GENERATOR.20259630018Electronic Modules61100028Electrical Control Equipment
Part Alternates: 77D609501G4, 77E300317G4, 6110-01-184-5560, 01-184-5560, 6110011845560, 011845560
Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | 19 JUL 1984 | 01-184-5560 | 00176 ( REGULATOR, VOLTAGE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6110-01-184-5560
Related Products | NSN 6110-01-184-5560
Technical Data | NSN 6110-01-184-5560
| Characteristic | Specifications |
|---|---|
| REGULATION METHOD | ANY ACCEPTABLE |
| RECOVERY TIME | 150.35 MICROSECONDS |
| OPERATING TEMP RANGE | -64.2 TO 69.0 DEG CELSIUS |
Restrictions/Controls & Freight Information | NSN 6110-01-184-5560
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
| Controlled Inventory Item Code: | Y | COMMUNICATION/ELECTRONIC EQUIPMENT AND PARTS |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 062920 | REGULATORS INDUCTION/VOLTAGE SUB2 |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 590 | unknown |
| Originating Activity Code | PA | Marine Corps Logistics Base Albany, GA 31704-1128 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | 2 | Arms/Weapons (all types including Inert Component Parts). When a 2 is indicated in the first position, then the special handling code must be determined from table 85 , part 1. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6110-01-184-5560
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 2 | Marine Corps Appropriation Stores Account Secondary Items. |
| Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
| Materiel Management Code | 4 | Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665 |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Operational Test Code | 0 | Items of supply which when properly packaged and placed in storage, do not require the performance of special procedures while in storage, nor prior to issue, and for which it has been determined that existing Care in Stores quality control procedures are adequate. |
| Physical Category Code | 1 | Bin |
| Source of Supply | MPB | Commanding General Marine Corps Logistics Command 566-2, Bldg. 3700 Albany, GA 31704-5000 |
| Agency | DM | U.S. Marine Corps |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | D | Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level. |
| Acquisition Advice Codes | U | LEAD SERVICE-MANAGED As a minimum provides procurement, disposal, and single submitter functions. Wholesale logistics responsibilities which are to be performed by the PICA in support of SICA are defined by the SICA NIMS Code. |
| Controlled Item Code | Y | COMMUNICATION/ELECTRONIC EQUIPMENT AND PARTS |
| Shelf Life Code | 0 | Nondeteriorative |