Product Details | VOLTAGE REGULATOR

6110-01-285-9686 A component within a single inclosure or provided with a single mounting specifically designed to control automatically the voltage output of an electrical system within certain required limits, regardless of variations of the effective load or of input voltages within a specific range. Does not include items in which regulation is accomplished solely by transformer action. See also REGULATOR SET, VOLTAGE. Excludes REGULATOR, ENGINE GENERATOR.20259630018Electronic Modules61100028Electrical Control Equipment

Part Alternates: 7583848P0046, 7583848P46, 7637643P0012, 7637643P12, 6110-01-285-9686, 01-285-9686, 6110012859686, 012859686

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 23 SEP 1988 01-285-9686

Cross Reference | NSN 6110-01-285-9686

Part Number Cage Code Manufacturer
7583848P0046 99971 LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE
7583848P46 99971 LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE
7637643P0012 99971 LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE
7637643P12 99971 LOCKHEED MARTIN CORP NAVAL ELECTRONICS & SURVEILLANCE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-01-285-9686

Technical Data | NSN 6110-01-285-9686

Characteristic Specifications
REGULATION METHOD ELECTRONIC
ELECTRONIC DEVICE TYPE SOLID STATE
CIRCUIT TYPE PARALLEL
INPUT CURRENT TYPE DC
INPUT VOLTAGE RATING IN VOLTS 16.0 MINIMUM AND 19.0 MAXIMUM
OUTPUT CURRENT TYPE DC
OUTPUT VOLTAGE RATING IN VOLTS 15.0 NOMINAL
OUTPUT CURRENT RATING 3.0 AMPERES MAXIMUM
RECOVERY TIME NOT RATED
OPERATING TEMP RANGE -55.0 TO 100.0 DEG CELSIUS
INCLOSURE FEATURE FULLY INCLOSED
OVERALL WIDTH 0.856 INCHES NOMINAL
OVERALL LENGTH 1.500 INCHES NOMINAL
OVERALL HEIGHT 0.570 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 6110-01-285-9686

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062920 REGULATORS INDUCTION/VOLTAGE
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6110-01-285-9686

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each