NSN 6115-00-313-8102 FFBSPZ376, L2211001, L221100-1
Product Details | ALTERNATING CURRENT GENERATOR
6115-00-313-8102 A generator having a characteristic of current and voltage that is continually reversing in direction of flow at regular intervals. Does not include rotary inverters, motor-generators, generator sets, synchros, and frequency or phase changers. Excludes GENERATOR, TACHOMETER.
Part Alternates: FFBSPZ376, L2211001, L221100-1, 6115-00-313-8102, 00-313-8102, 6115003138102, 003138102
Electric Wire, and Power and Distribution Equipment | Generators and Generator Sets, Electrical
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | 01 JAN 1963 | 00-313-8102 | 00781 ( GENERATOR, ALTERNATING CURRENT ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6115-00-313-8102
Related Products | NSN 6115-00-313-8102
Technical Data | NSN 6115-00-313-8102
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 4.730 INCHES |
| OVERALL WIDTH | 2.250 INCHES |
| OVERALL HEIGHT | 2.250 INCHES |
| LENGTH OF SHAFT FROM HOUSING | 1.600 INCHES SINGLE END |
| MOUNTING METHOD | END BELL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| MOUNTING FACILITY CIRCLE DIAMETER | 1.250 INCHES |
| INCLOSURE FEATURE | TOTALLY INCLOSED |
| INCLOSURE SPECIFICATION | COMMERCIAL |
| FREQUENCY IN HERTZ | 15.0 OUTPUT |
| PHASE | TWO OUTPUT |
| CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 9.0 LINE TO LINE SINGLE OUTPUT |
| POWER RATING | 0.020 WATTS OUTPUT |
| WINDING TYPE | SYNCHRONOUS |
| EXCITOR TYPE | SEPARATELY EXCITED |
| DUTY CYCLE | CONTINUOUS |
| TEMP RATING | -55.0 OPERATING DEG CELSIUS AND 65.0 OPERATING DEG CELSIUS |
| COOLING METHOD | NATURAL CONVECTION VENTILATED |
| TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
| SHAFT ROTATION DIRECTION | CLOCKWISE SINGLE END |
| ROTOR SPEED RATING IN RPM | 900.0 SINGLE NO LOAD |
| SHAFT END CHARACTERISTIC | A5 SINGLE STYLE SINGLE END |
| SHAFT DIAMETER | 0.2490 INCHES NOMINAL SINGLE END |
| FLATTED PORTION LENGTH | 0.500 INCHES NOMINAL SINGLE END |
| FLAT DEPTH | 0.019 INCHES NOMINAL SINGLE END |
| FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
| MANUFACTURERS CODE | 06845 |
| DESIGN CONTROL REFERENCE | L221100-1 |
Restrictions/Controls & Freight Information | NSN 6115-00-313-8102
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 062120 | GENERATORS/MOTORS/PARTS NOI |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 590 | unknown |
| Originating Activity Code | XX | |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6115-00-313-8102
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9G | Navy-owned stocks of defense general material Naval Inventory Control Point, Mechanicsburg |
| Issue Repair, or Requisition | R9 | Integrated Manager reparable item. Includes Defense Logistics Agency-managed items which are reportable in non-RFI condition to appropriate Defense Supply Center per NAVSUP instructions for return of excess material to DLA. |
| Source of Supply | S9G | Defense Supply Center Richmond Richmond, VA 23297 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |