Product Details | POWER TRANSFORMER

6120-01-485-4744 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: P77, 6120-01-485-4744, 01-485-4744, 6120014854744, 014854744

Electric Wire, and Power and Distribution Equipment | Transformers: Distribution and Power Station

Supply Group (FSG) NSN Assign. NIIN
61 29 MAY 2001 01-485-4744

Cross Reference | NSN 6120-01-485-4744

Part Number Cage Code Manufacturer
P77 54241 MYERS POWER PRODUCTS, INC. DBA MYERS/ABACUS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6120-01-485-4744

Technical Data | NSN 6120-01-485-4744

Characteristic Specifications
FREQUENCY RATING 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE FULLY INCLOSED
OVERALL HEIGHT 24.380 INCHES NOMINAL
OVERALL WIDTH 19.750 INCHES NOMINAL
SPECIAL FEATURES PRIMARY INPUT VOLTAGE: 220VAC, 380VAC, 440VAC PORM 5PCT; 3 PHASE 3 WIRE CONFIGURATION; ALTERNATE INPUT: 24VDC, 30ADC; OUTPUT VOLTAGE: 24 VDC PORM 10PCT; 30 ADC MAX CURRENT; PROTECTION: 30 ADC, 500VDC FUSED OUTPUT; WALL MOUNTED

Restrictions/Controls & Freight Information | NSN 6120-01-485-4744

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information