Product Details | METALLIC RECTIFIER

6130-00-230-8354 An electrical item (the working element of which is constructed essentially of metallic substances) which changes alternating current to direct current by the rectifying action occurring at the junction interface between a metallic conductor and a semiconductor. Excludes sets of metallic rectifiers which are not rated for rectifying capabilities but are used as suppressors. For items containing germanium or silicon, see SEMICONDUCTOR DEVICE (1), DIODE; SEMICONDUCTOR DEVICE SET and RECTIFIER, SEMICONDUCTOR DEVICE. For a complete power supply utilizing metallic rectifiers, see POWER SUPPLY.

Part Alternates: P2B1ST3BKX, 6130-00-230-8354, 00-230-8354, 6130002308354, 002308354

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 30 DEC 1971 00-230-8354

Cross Reference | NSN 6130-00-230-8354

Part Number Cage Code Manufacturer
P2B1ST3BKX 81483 INTERNATIONAL RECTIFIER CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-00-230-8354

Technical Data | NSN 6130-00-230-8354

Characteristic Specifications
MATERIAL SELENIUM
RMS INPUT MAXIMUM VOLTAGE RATING 66.0 VOLTS
DC OUTPUT MAXIMUM CURRENT RATING 6.500 AMPERES
LOAD TYPE INDUCTIVE AND RESISTIVE
DC OUTPUT MAXIMUM VOLTAGE RATING 66.0 VOLTS NEW
STACK QUANTITY 1
TEMP RATING 35.0 DEG CELSIUS
OVERALL LENGTH 4.187 INCHES NOMINAL
OVERALL WIDTH 4.000 INCHES NOMINAL
OVERALL HEIGHT 4.000 INCHES NOMINAL
TERMINAL QUANTITY 4
TERMINAL TYPE SOLDER LUG
GROUNDED TERMINAL NOT INCLUDED
MOUNTING METHOD STUD
MOUNTING CONFIGURATION ONE 0.375 IN. - 16 THD BY 0.750 IN. LG STUD CENTRALLY LOCATEDEACH END

Restrictions/Controls & Freight Information | NSN 6130-00-230-8354

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062900 RECTIFIERS NOI/BATTERY ELIMINATORS
Less than car load rating M 85
Less than truck load rating M 85.0
Water commodity Code 658 unknown
Originating Activity Code CL U.S. Army Communications-Electronics
Fort Monmouth, NJ 07703-5006
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable