Product Details | METALLIC RECTIFIER

6130-00-635-9769 An electrical item (the working element of which is constructed essentially of metallic substances) which changes alternating current to direct current by the rectifying action occurring at the junction interface between a metallic conductor and a semiconductor. Excludes sets of metallic rectifiers which are not rated for rectifying capabilities but are used as suppressors. For items containing germanium or silicon, see SEMICONDUCTOR DEVICE (1), DIODE; SEMICONDUCTOR DEVICE SET and RECTIFIER, SEMICONDUCTOR DEVICE. For a complete power supply utilizing metallic rectifiers, see POWER SUPPLY.

Part Alternates: S40D1FN7, 6130-00-635-9769, 00-635-9769, 6130006359769, 006359769

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 01 JAN 1961 00-635-9769

Cross Reference | NSN 6130-00-635-9769

Part Number Cage Code Manufacturer
S40D1FN7 58849 FMC TECHNOLOGIES INC DIV MATERIAL HANDLING SOLUTIONS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-00-635-9769

Technical Data | NSN 6130-00-635-9769

Characteristic Specifications
MATERIAL SELENIUM
RMS INPUT MAXIMUM VOLTAGE RATING 40.0 VOLTS
DC OUTPUT MAXIMUM CURRENT RATING 27.000 AMPERES
LOAD TYPE CAPACITIVE
DC OUTPUT MAXIMUM VOLTAGE RATING 75.0 VOLTS NEW
STACK QUANTITY 1
TEMP RATING 35.0 DEG CELSIUS
OVERALL LENGTH 7.312 INCHES NOMINAL
OVERALL WIDTH 6.000 INCHES NOMINAL
OVERALL HEIGHT 5.000 INCHES NOMINAL
TERMINAL QUANTITY 3
TERMINAL TYPE THREADED STUD
GROUNDED TERMINAL NOT INCLUDED
MOUNTING METHOD STUD
MOUNTING CONFIGURATION ONE NO. 3/8 -16 THD MTG STUD AXIALLY LOCATED

Restrictions/Controls & Freight Information | NSN 6130-00-635-9769

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062900 RECTIFIERS NOI/BATTERY ELIMINATORS
Less than car load rating
Less than truck load rating M 85.0
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable