Product Details | METALLIC RECTIFIER

6130-00-643-2151 An electrical item (the working element of which is constructed essentially of metallic substances) which changes alternating current to direct current by the rectifying action occurring at the junction interface between a metallic conductor and a semiconductor. Excludes sets of metallic rectifiers which are not rated for rectifying capabilities but are used as suppressors. For items containing germanium or silicon, see SEMICONDUCTOR DEVICE (1), DIODE; SEMICONDUCTOR DEVICE SET and RECTIFIER, SEMICONDUCTOR DEVICE. For a complete power supply utilizing metallic rectifiers, see POWER SUPPLY.

Part Alternates: M7471320REV4, 6RS118CH1, 6RS126C1, 6RS5CH35, 20318, 6130-00-643-2151, 00-643-2151, 6130006432151, 006432151

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 01 JAN 1963 00-643-2151

Cross Reference | NSN 6130-00-643-2151

Part Number Cage Code Manufacturer
20318 80064 NAVAL SHIP SYSTEMS COMMAND
6RS118CH1 24446 GENERAL ELECTRIC CO
6RS126C1 24446 GENERAL ELECTRIC CO
6RS5CH35 24446 GENERAL ELECTRIC CO
M7471320REV4 24446 GENERAL ELECTRIC CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-00-643-2151

Technical Data | NSN 6130-00-643-2151

Characteristic Specifications
MATERIAL SELENIUM
ABSOLUTE MAXIMUM POWER RATING PER CHARACTERISTIC 187.2 WATTS TOTAL POWER DISSIPATION
RMS INPUT MAXIMUM VOLTAGE RATING 234.0 VOLTS
DC OUTPUT MAXIMUM CURRENT RATING 800.000 MILLIAMPERES
LOAD TYPE RESISTIVE
DC OUTPUT MAXIMUM VOLTAGE RATING 156.0 VOLTS NEW
STACK QUANTITY 1
TEMP RATING -50.0 DEG CELSIUS AND 60.0 DEG CELSIUS
ENVIRONMENTAL PROTECTION MOISTURE
OVERALL LENGTH 7.250 INCHES NOMINAL
OVERALL DIAMETER 2.188 INCHES NOMINAL
TERMINAL QUANTITY 3
TERMINAL TYPE SOLDER LUG
GROUNDED TERMINAL NOT INCLUDED
MOUNTING METHOD STUD
MOUNTING CONFIGURATION TWO 1/4 IN. -20 THD STUDS ONE ON EA END
III END ITEM IDENTIFICATION MODEL NO. TDZ
MANUFACTURERS CODE 24446
DESIGN CONTROL REFERENCE 6RS5CH35

Restrictions/Controls & Freight Information | NSN 6130-00-643-2151

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062900 RECTIFIERS NOI/BATTERY ELIMINATORS
Less than car load rating M 85
Less than truck load rating M 85.0
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable