NSN 6130-01-043-4062 01P01450L001, 53P07821H001, 53-P07821H001
Product Details | POWER SUPPLY
6130-01-043-4062 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.20461200044Transformers: Distribution and Power Station61300035Converters, Electrical, Nonrotating65150057Medical and Surgical Instruments, Equipment, and Supplies65200043Dental Instruments, Equipment, and Supplies
Part Alternates: 01P01450L001, 53P07821H001, 53-P07821H001, 6130-01-043-4062, 01-043-4062, 6130010434062, 010434062
Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | 23 JUN 1977 | 01-043-4062 | 00740 ( POWER SUPPLY ) |
Cross Reference | NSN 6130-01-043-4062
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6130-01-043-4062
Technical Data | NSN 6130-01-043-4062
| Characteristic | Specifications |
|---|---|
| OUTPUT VOLTAGE RATING | 16.0 DC KILOVOLTS NOMINAL SINGLE POWER OUTPUT |
| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ENVIRONMENTAL PROTECTION | HERMETICALLY SEALED |
| MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET |
| OVERALL LENGTH | 4.880 INCHES NOMINAL |
| OVERALL WIDTH | 3.130 INCHES NOMINAL |
| OVERALL HEIGHT | 2.000 INCHES NOMINAL |
| OPERATING AMBIENT TEMP RANGE | -55.0 TO 71.0 DEG CELSIUS |
| MANUFACTURERS CODE | 94990 |
| DESIGN CONTROL REFERENCE | 01P01450L001 |
Restrictions/Controls & Freight Information | NSN 6130-01-043-4062
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||
Management | NSN 6130-01-043-4062
| Category | Code | Description |
|---|---|---|
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
| Source of Supply | FGZ | Ogden Air Logistics Center Hill AFB, UT 84056-5609 |
| Agency | DF | Department of the Air Force |
| Service Organization | F | U.S. Air Force |
| Reparability | T | AF Recoverable Assembly Management System (AFRAMS) |
| Acquisition Advice Codes | C | SERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 2 | Marine Corps Appropriation Stores Account Secondary Items. |
| Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
| Materiel Management Code | 4 | Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665 |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Operational Test Code | 0 | Items of supply which when properly packaged and placed in storage, do not require the performance of special procedures while in storage, nor prior to issue, and for which it has been determined that existing Care in Stores quality control procedures are adequate. |
| Source of Supply | MPB | Commanding General Marine Corps Logistics Command 566-2, Bldg. 3700 Albany, GA 31704-5000 |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | D | Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level. |
| Acquisition Advice Codes | C | SERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 7G | Depot level reparable electronic material to support Naval Inventory Control Point, Space and Naval Warfare Systems Command, Mechanicsburg |
| Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
| Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
| Agency | DN | Department of the Navy |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | H | Depot Level Reparable |
| Acquisition Advice Codes | C | SERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |