NSN 6130-01-350-8053 010162, 01-350-8053, 013508053
Product Details | POWER SUPPLY ASSEMBLY
6130-01-350-8053 Two or more independent power supplies having a common mounting or mounted on each other.
Part Alternates: 010162, 6130-01-350-8053, 01-350-8053, 6130013508053, 013508053
Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | 01-350-8053 | 00295 ( POWER SUPPLY ASSEMBLY ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6130-01-350-8053
Related Products | NSN 6130-01-350-8053
Technical Data | NSN 6130-01-350-8053
| Characteristic | Specifications |
|---|---|
| OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT 9.0 DC VOLTS NOMINAL 2ND POWER OUTPUT -15.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
| OUTPUT CURRENT RATING | 750.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT 7.5 DC AMPERES NOMINAL 2ND POWER OUTPUT -750.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT |
| OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
| OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
| ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| INPUT VOLTAGE RATING | 230.0 AC VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT 115.0 AC VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
| INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
| POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER SINGLE OPERATING POWER RQMT |
| POWER UNIT QUANTITY | 2 |
| OPERATING AMBIENT TEMP RANGE | -0.0 TO 40.0 DEG CELSIUS |
| RELATIONSHIP TO SIMILAR EQUIPMENT | THIS POWER SUPPLY ASSEMBLY CONSIST OF P/N XM15-15 NSN 6130-01-242-5546 AND P/N XPX45-5 NSN 6130-01-242-2163 |
| MANUFACTURERS CODE | 55744 |
| DESIGN CONTROL REFERENCE | 010162 |
Restrictions/Controls & Freight Information | NSN 6130-01-350-8053
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||