Product Details | POWER SUPPLY

6130-01-363-0912 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.20461200044Transformers: Distribution and Power Station61300035Converters, Electrical, Nonrotating65150057Medical and Surgical Instruments, Equipment, and Supplies65200043Dental Instruments, Equipment, and Supplies

Part Alternates: 5002, 500-2, 6130-01-363-0912, 01-363-0912, 6130013630912, 013630912

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 21 AUG 1992 01-363-0912

Demand History | NSN 6130-01-363-0912

Part Number Request Date QTY Origin
5002 2021-04-106 2 MY
5002 2020-02-41 2 us

Cross Reference | NSN 6130-01-363-0912

Part Number Cage Code Manufacturer
500-2 25965 AMETEK PROGRAMMABLE POWER, INC. DBA AMTEK NORTH

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-01-363-0912

Technical Data | NSN 6130-01-363-0912

Characteristic Specifications
OUTPUT VOLTAGE RATING 0.0 AC VOLTS MINIMUM AND 32.0 AC VOLTS MAXIMUM 1ST POWER OUTPUT 0.0 AC VOLTS MINIMUM AND 130.0 AC VOLTS MAXIMUM 2ND POWER OUTPUT 0.0 AC VOLTS MINIMUM AND 260.0 AC VOLTS MAXIMUM 3RD POWER OUTPUT
OUTPUT CURRENT RATING 0.0 AC AMPERES MINIMUM AND 9.2 AC AMPERES MAXIMUM 1ST POWER OUTPUT 0.0 AC AMPERES MINIMUM AND 2.25 AC AMPERES MAXIMUM 2ND POWER OUTPUT 0.0 AC AMPERES MINIMUM AND 1.1 AC AMPERES MAXIMUM 3RD POWER OUTPUT
OUTPUT PHASE TWO 1ST POWER OUTPUT TWO 2ND POWER OUTPUT TWO 3RD POWER OUTPUT
OUTPUT FREQUENCY RATING 45.0 HERTZ MINIMUM AND 5.0 KILOHERTZ MAXIMUM 1ST POWER OUTPUT 45.0 HERTZ MINIMUM AND 5.0 KILOHERTZ MAXIMUM 2ND POWER OUTPUT 45.0 HERTZ MINIMUM AND 5.0 KILOHERTZ MAXIMUM 3RD POWER OUTPUT
OUTPUT CONTROL LOCATION REAR PANEL 1ST POWER OUTPUT REAR PANEL 2ND POWER OUTPUT REAR PANEL 3RD POWER OUTPUT
OUTPUT CONNECTION QUANTITY 1 1ST POWER OUTPUT 1 2ND POWER OUTPUT 1 3RD POWER OUTPUT
OUTPUT CONNECTION TYPE TERMINAL STRIP 1ST POWER OUTPUT TERMINAL STRIP 2ND POWER OUTPUT TERMINAL STRIP 3RD POWER OUTPUT
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
INPUT VOLTAGE RATING 115.0 AC VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT 230.0 AC VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING 1500.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT 1500.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
INPUT PHASE SINGLE 1ST ALTERNATE OPERATING POWER RQMT SINGLE 2ND ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION TYPE TERMINAL STRIP 1ST ALTERNATE OPERATING POWER RQMT TERMINAL STRIP 2ND ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY 1 1ST ALTERNATE OPERATING POWER

Restrictions/Controls & Freight Information | NSN 6130-01-363-0912

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 062900 RECTIFIERS NOI/BATTERY ELIMINATORS
Less than car load rating M 85
Less than truck load rating M 85.0
Water commodity Code 593 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6130-01-363-0912

Category Code Description
Cognizance Codes6RAeronautical ground support equipment (reparable or investment type material)
Naval Inventory Control Point, Philadelphia
Special Material IDGF (Non-HSP) FIGHTER SUPPORTAIRCRAFT(F/A-18)
Issue Repair, or RequisitionBSSubmit/refer requisitions to NAVICP PHIL.
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityXSpecial Program Reparables
Acquisition Advice CodesMRESTRICTED REQUISITIONS-MAJOR OVERHAUL (Service/Agency use only.) # Items (Assemblies and/or component parts) which for lack of specialized tools, test equipment, etc., can be used only by major overhaul activities. Base, post, camp or station activities will not requisition unless authorized to perform major overhaul function.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each