Product Details | POWER SUPPLY ASSEMBLY

6130-01-457-5478 Two or more independent power supplies having a common mounting or mounted on each other.

Part Alternates: S10398, 9478382-01, 6130-01-457-5478, 01-457-5478, 6130014575478, 947838201, 014575478

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 01-457-5478

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-01-457-5478

Technical Data | NSN 6130-01-457-5478

Characteristic Specifications
OUTPUT VOLTAGE RATING 5.0 DC VOLTS NOMINAL 1ST POWER OUTPUT 15.0 DC VOLTS NOMINAL 2ND POWER OUTPUT 15.0 DC VOLTS NOMINAL 3RD POWER OUTPUT 24.0 DC VOLTS NOMINAL 4TH POWER OUTPUT 28.0 DC VOLTS NOMINAL 5TH POWER OUTPUT
OUTPUT CURRENT RATING 2.0 DC AMPERES NOMINAL 1ST POWER OUTPUT 0.25 DC AMPERES NOMINAL 2ND POWER OUTPUT 0.25 DC AMPERES NOMINAL 3RD POWER OUTPUT 2.1 DC AMPERES NOMINAL 4TH POWER OUTPUT 0.5 DC AMPERES NOMINAL 5TH POWER OUTPUT
OUTPUT CONNECTION QUANTITY 5 SINGLE POWER OUTPUT
OUTPUT CONNECTION TYPE SCREW SINGLE POWER OUTPUT
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
INPUT VOLTAGE RATING 105.0 AC VOLTS MINIMUM AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
INPUT FREQUENCY RATING 50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
INPUT PHASE SINGLE SINGLE OPERATING POWER RQMT
POWER UNIT TYPE REGULATOR SINGLE OPERATING POWER RQMT
POWER UNIT QUANTITY 3
OVERALL LENGTH 19.000 INCHES NOMINAL
OVERALL WIDTH 5.250 INCHES NOMINAL
MAJOR COMPONENTS POWER SUPPLY P/N 3V51515T5A; POWER SUPPLY P/N VRB24G210;POWER SUPPLY P/N VRG28G50
OPERATING AMBIENT TEMP RANGE 0.0 TO 71.0 DEG CELSIUS
SPECIAL FEATURES ELECTROSTATIC SENSITIVE;FRONT PANEL EQUIPPED WITH AC INPUT SWITCH,VOLTMETER,AMMETER,METER SWITCH AND HANDLES
CRITICALITY CODE JUSTIFICATION FEAT
III PART NAME ASSIGNED BY CONTROLLING AGENCY DC POWER SUPPLY

Restrictions/Controls & Freight Information | NSN 6130-01-457-5478

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Electro-static Discharge Susceptible:BESD sensitivity
Category Code Description
No Freight Information