Product Details | STATIC POWER INVERTER

6130-01-553-4886 An item that changes a direct current input into a single or multiple phase alternating current output, by the combined action of oscillators, semiconductor devices, magnetic amplifiers, phase splitters, and the like. For items that perform the same function by means of rotating machine techniques, see MOTOR-GENERATOR. See also CONVERTER, FREQUENCY, STATIC.

Part Alternates: SPC30C, 6130-01-553-4886, 01-553-4886, 6130015534886, 015534886

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 17 JUL 2007 01-553-4886

Cross Reference | NSN 6130-01-553-4886

Part Number Cage Code Manufacturer
SPC-30(C) 0HUV8 KGS ELECTRONICS UPLAND PLANT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-01-553-4886

Technical Data | NSN 6130-01-553-4886

Characteristic Specifications
OUTPUT VOLTAGE RATING 115.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT
OUTPUT PHASE SINGLE SINGLE POWER OUTPUT
OUTPUT WAVEFORM AND CURRENT TYPE FULL WAVE RECTIFIED SINE WAVE AC SINGLE POWER OUTPUT
INPUT VOLTAGE RATING 28.0 DC VOLTS NOMINAL SINGLE OPERATING POWER RQMT
INPUT CURRENT RATING 16.0 DC AMPERES NOMINAL SINGLE OPERATING POWER RQMT
MAXIMUM OPERATING ALTITUDE RATING 55000.0 FEET
OVERALL LENGTH 10.620 INCHES NOMINAL
OVERALL WIDTH 6.000 INCHES NOMINAL
OVERALL HEIGHT 3.220 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE -65.0 TO 160.0 DEG FAHRENHEIT
III END ITEM IDENTIFICATION ARMED FORCES OF THE SLOVAK REPUBLIC (MI-17 HELICOPTER)
III PART NAME ASSIGNED BY CONTROLLING AGENCY TSO'D 300 VA STATIC INVERTER

Restrictions/Controls & Freight Information | NSN 6130-01-553-4886

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information