Product Details | UNINTERRUPTIBLE POWER SUPPLY

6130-01-587-6916 An item that provides continuous backup power to electronic devices in the event of a utility power dip or blackout. It generally contains a battery and a power inverter that provides the necessary backup power in the event of a loss of normal input utility power. It may also contain a power line filter or power line conditioning devices. Excludes power supplies without standby power, electrical power inverers, and batteries.

Part Alternates: SMART1000RM2U, 6130-01-587-6916, 01-587-6916, 6130015876916, 015876916

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 17 AUG 2010 01-587-6916

Cross Reference | NSN 6130-01-587-6916

Part Number Cage Code Manufacturer
SMART1000RM2U 65836 TRIPPE MANUFACTURING COMPANY DBA DATA SHIELD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-01-587-6916

Technical Data | NSN 6130-01-587-6916

Characteristic Specifications
VENTILATION DESIGN TYPE SINGLE FAN
SPECIAL FEATURES OUTPUT KVA CAPACITY: 1;OUTPUT POWER FACTOR: 0.7;OUTPUT VOLTAGE REGULATION (LINE MODE) MINUS 21 PERCENT,PLUS 8 PERCENT;BUILT-IN UPS OUTPUT RECEPTACLES: 6 5-15R OUTLETS;;OUTPUT VOLTAGE REGULATION (BATTERY MODE) PLUS OR MINUS 5 PERCENT;BUILT-IN CONTROLLABLE SWITCHED LOAD BANKS: TWO SWITCHABLE TWO-OUTLET 5-15R LOAD BANKS;RATED INPUT CURRENT (AT MAXIMUM LOAD) 6.8A;UPS INPUT CONNECTION TYPE: 5-15P;INPUT CIRCUIT BREAKER: 15A;UPS INPUT CORD LENGTH: 3 M;RECOMMENDED ELECTRICAL SERVICE: 15A 120V;BATTERY: FULL LOAD RUNTIME: 7 MINUTES (700W),HALF LOAD RUNTIME: 17 MINUTES (350W),DC SYSTEM VOLTAGE: 24 DC,BATTERY RECHARGE RATE: LESS THAN 4 HOURS FROM 10 PERCENT TO 90 PERCENT
BATTERY LOCATION INTERNAL
OUTPUT CURRENT RATING 1000.0 AC VOLT-AMPERE NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT WAVEFORM AND CURRENT TYPE SINUSOIDAL AC MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
INPUT VOLTAGE RATING 120.0 AC VOLTS NOMINAL SINGLE OPERATING POWER RQMT
PART NAME ASSIGNED BY CONTROLLING AGENCY 1000VA,RACKMOUNT 2 UNIT,120V
OUTPUT FREQUENCY RATING 60.0 HERTZ NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT WATTAGE RATING 700.0 WATTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT VOLTAGE RATING 120.0 AC VOLTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS

Restrictions/Controls & Freight Information | NSN 6130-01-587-6916

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information