NSN 6140-00-227-8555 EP12240, EP1224034, EP12240-34
Product Details | STORAGE BATTERY
6140-00-227-8555 A battery, composed of two or more cells forming a single unit, which may or may not be readily separable and which may be efficiently recharged by sending an electric current through the cells in a direction opposite that of the discharging current. The item may be furnished with integral charging facilities. For items which are composed of a single cell see CELL, BATTERY.
Part Alternates: EP12240, EP1224034, EP12240-34, GC12200 TYPE B, GC12200A, GC12200TYPEB, GC12230, GC122306, GC12230-6, GC122306A, GC12230-6A, GC12230TYPE A, GC12230TYPEA, JC12250, PS12200, PS-12200, 1004913-01, 1004913-03, 10049132, 1004913-2, 138C682H01, 1004913-02, 6140-00-227-8555, 00-227-8555, 6140002278555, 100491301, 100491302, 002278555, 100491303
Electric Wire, and Power and Distribution Equipment | Batteries, Rechargeable
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | 20 MAY 1973 | 00-227-8555 | 00013 ( BATTERY, STORAGE ) |
Demand History | NSN 6140-00-227-8555
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 6140-00-227-8555 | 2012-04-118 | 15 | PK |
Cross Reference | NSN 6140-00-227-8555
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 1004913-01 | 36378 | RAYTHEON TECHNICAL SERVICES COMPANY |
| 1004913-02 | 36378 | RAYTHEON TECHNICAL SERVICES COMPANY |
| 1004913-03 | 1PQF4 | L-3 COMMUNICATIONS CORPORATION DBA LINK SIMULATION & TRAINING |
| 1004913-03 | 36378 | RAYTHEON TECHNICAL SERVICES COMPANY |
| 1004913-2 | 36378 | RAYTHEON TECHNICAL SERVICES COMPANY |
| 138C682H01 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS |
| EP12240 | 31743 | ELDON INDUSTRIES INC ELPOWER CORP |
| EP12240-34 | 31743 | ELDON INDUSTRIES INC ELPOWER CORP |
| GC12200 TYPE B | 25244 | JOHNSON CONTROLS, INC. DBA JOHNSON CONTROLS |
| GC12200A | 25244 | JOHNSON CONTROLS, INC. DBA JOHNSON CONTROLS |
| GC12230 | 25244 | JOHNSON CONTROLS, INC. DBA JOHNSON CONTROLS |
| GC12230-6 | 25244 | JOHNSON CONTROLS, INC. DBA JOHNSON CONTROLS |
| GC12230-6A | 25244 | JOHNSON CONTROLS, INC. DBA JOHNSON CONTROLS |
| GC12230TYPE A | 25244 | JOHNSON CONTROLS, INC. DBA JOHNSON CONTROLS |
| JC12250 | 25244 | JOHNSON CONTROLS, INC. DBA JOHNSON CONTROLS |
| PS-12200 | 56309 | POWER-SONIC CORPORATION |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6140-00-227-8555
Technical Data | NSN 6140-00-227-8555
| Characteristic | Specifications |
|---|---|
| BATTERY ELECTROLYTE | SILICA-GEL |
| VOLTAGE IN VOLTS | 12.0 |
| AMPERE HOUR CAPACITY | 23.00 |
| TIME CAPACITY IN HOURS | 20.00 |
| DISCHARGE RATE IN AMPS | 1.00 |
| DISCHARGE TIME IN MINUTES | 1200.0 |
| LOW TEMP AMPERE HOUR CAPACITY | 20.00 |
| TEMP RATING | 60.0 DEG CELSIUS |
| TERMINAL QUANTITY | 2 |
| TERMINAL TYPE | QUICK DISCONNECT W/LEADS |
| CELL QUANTITY | 6 |
| PLATE MATERIAL | CALCIUM LEAD |
| PLATE TYPE | NEGATIVE AND POSITIVE |
| PLATE QUANTITY PER CELL | 6 |
| SEPARATOR MATERIAL | PLASTIC |
| OVERALL WIDTH | 6.940 INCHES NOMINAL |
| OVERALL LENGTH | 6.590 INCHES NOMINAL |
| OVERALL HEIGHT | 4.920 INCHES NOMINAL |
| CASE MATERIAL | PLASTIC, POLYSTYRENE |
| CASE DESIGN TYPE | SEALED |
| NONSPILLING FEATURE | NOT INCLUDED |
| PORTABILITY METHOD | ANY ACCEPTABLE |
| CHARGE INDICATOR | NOT INCLUDED |
| ELECTROLYTE LEVEL INDICATOR | NOT INCLUDED |
| FORDING FEATURE | NOT INCLUDED |
| STORAGE/SHIPMENT CONDITION | WET CHARGED |
| INTEGRAL CHARGING FACILITY | NOT INCLUDED |
Restrictions/Controls & Freight Information | NSN 6140-00-227-8555
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | Y | Information is in the Hazardous Materials Information System (HMIS) |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Hazardous Control Code: | C1 | Acid, Corrosive, Inorganic ACID, CORR, INORGANIC |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 060680 | BATTERIES OR CELL |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 582 | unknown |
| Originating Activity Code | 47 | National Weather Service Silver Spring, MD 20910 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | V | Miscellaneous hazardous materials, UN class 9 (no label) |
Management | NSN 6140-00-227-8555
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9G | Navy-owned stocks of defense general material Naval Inventory Control Point, Mechanicsburg |
| Special Material Content | C | Corrosive Solids/Corrosive Liquid (other than Acid) |
| Source of Supply | S9G | Defense Supply Center Richmond Richmond, VA 23297 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |