Product Details | ELECTRICAL POWER CABLE

6145-00-125-5274 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000

Part Alternates: MILC915TYPETC0P3, TC0P3, 15C13C0NDUCT0RS16AWG, 15C1-3C0NDUCT0RS16AWG, 15C1ANDTYPETC0P3, 735077BULKCABLE, 73-5077BULKCABLE, 6145-00-125-5274, 00-125-5274, 6145001255274, 001255274

Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical

Supply Group (FSG) NSN Assign. NIIN
61 01 JAN 1963 00-125-5274

Drawings & Photos | NSN 6145-00-125-5274


Cross Reference | NSN 6145-00-125-5274

Part Number Cage Code Manufacturer
15C1-3C0NDUCT0RS16AWG 80064 NAVAL SHIP SYSTEMS COMMAND
15C1ANDTYPETC0P3 99993 DEPARTMENT OF THE NAVY
73-5077BULKCABLE 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
73-5077BULKCABLE 49956 RAYTHEON COMPANY DBA RAYTHEON
MILC915TYPETC0P3 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
TC0P3 24446 GENERAL ELECTRIC CO
TC0P3 99993 DEPARTMENT OF THE NAVY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6145-00-125-5274

Technical Data | NSN 6145-00-125-5274

Characteristic Specifications
CONDUCTOR QUANTITY 3
CONDUCTOR FORM STRANDED ALL CONDUCTORS
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE 16 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR 26 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR 30 ALL CONDUCTORS
VOLTAGE RATING 2000.0 DIELECTRIC TEST VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
CROSS SECTION OUTSIDE DIAMETER 0.450 INCHES NOMINAL
SPECIAL FEATURES RESISTANT TO OIL
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MILC915TYPETC0P3

Restrictions/Controls & Freight Information | NSN 6145-00-125-5274

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 030310 CABLE OR WIRE
Less than car load rating S 60
Less than truck load rating W Rating Variable
Water commodity Code 743 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable