Product Details | ELECTRICAL POWER CABLE

6145-01-318-4756 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000

Part Alternates: MA3883, MA-3883, 6145-01-318-4756, 01-318-4756, 6145013184756, 013184756

Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical

Supply Group (FSG) NSN Assign. NIIN
61 19 APR 1990 01-318-4756

Drawings & Photos | NSN 6145-01-318-4756


Cross Reference | NSN 6145-01-318-4756

Part Number Cage Code Manufacturer
MA-3883 0RY20 M C M ENGINEERING INC
MA-3883 1F896 MCCORMICK MORGAN INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6145-01-318-4756

Technical Data | NSN 6145-01-318-4756

Characteristic Specifications
CONDUCTOR QUANTITY 25
CONDUCTOR FORM STRANDED ALL CONDUCTORS
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS RUBBER CHLOROPRENE CLASS CR 1ST POSITION JACKET CABLE
MATERIAL DOCUMENT AND CLASSIFICATION ASTM B3 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR 34 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY 7 SINGLES AND 6 TRIPLES
COLOR CODING DOCUMENT MA-3883-1F896 SPECIFICATION
COLOR BLACK 1ST POSITION JACKET CABLE
VOLTAGE RATING 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
CROSS SECTION OUTSIDE DIAMETER 2.000 INCHES NOMINAL
TEMP RATING -55.0 DEG CELSIUS AND 65.0 DEG CELSIUS
SPECIAL FEATURES CABLE CONTAINS 6 SIZE 2 AWG POWER CONDUCTORS,18 SIZE 18 CONTROL CONDUCTORS,AND 1 SIZE 2/0 AWG NEUTRAL CONDUCTOR AND OUTER JACKET IS RAYON REINFORCED

Restrictions/Controls & Freight Information | NSN 6145-01-318-4756

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 030310 CABLE OR WIRE
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 743 unknown
Originating Activity Code KZ Defense Supply Center Philadelphia
Philadelphia, PA 19101
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6145-01-318-4756

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
FT : Foot