Product Details | ELECTRICAL POWER CABLE

6145-01-626-1053 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000

Part Alternates: SJ143, SJ14-3 , 6145-01-626-1053, 01-626-1053, 6145016261053, 016261053

Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical

Supply Group (FSG) NSN Assign. NIIN
61 2014057 01-626-1053

Demand History | NSN 6145-01-626-1053

Part Number Request Date QTY Origin
SJ14-3 2020-04-103 250 DIBBS
6145-01-626-1053 2018-01-28 40 DIBBS

Cross Reference | NSN 6145-01-626-1053

Part Number Cage Code Manufacturer
SJ14-3 58961 WAYTEK, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6145-01-626-1053

Technical Data | NSN 6145-01-626-1053

Characteristic Specifications
III CONDUCTOR QUANTITY 3
CONDUCTOR FORM STRANDED ALL CONDUCTORS
III MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE 14 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR 41 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR 30 ALL CONDUCTORS
CONDUCTOR CROSS-SECTIONAL SHAPE TUBULAR BRAID ALL CONDUCTORS
OUTSIDE DIAMETER 0.370 INCHES NOMINAL ALL CONDUCTORS
COLOR BLACK CORE JACKET OVERALL
VOLTAGE RATING 300.0 SERVICE VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLE ROUND
TEMP RATING -40.0 DEG CELSIUS AND
SPECIAL FEATURES CERTIFIED FOR INDOOR AND OUTDOOR USE; RESISTANCE TO OIL AND WATER, EXCELLANT ABRASION RESISTANCE
III END ITEM IDENTIFICATION MRAP BUFFALO MK2A2

Restrictions/Controls & Freight Information | NSN 6145-01-626-1053

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 030310 CABLE OR WIRE
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 743 unknown
Originating Activity Code GX HQ Defense Logistics Agency, Enterprise Business
Systems
Fort Belvoir, VA 22060
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6145-01-626-1053

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code5Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative