Product Details | ELECTRICAL POWER CABLE ASSEMBLY

6150-00-952-2677 A definite continuous length of CABLE, POWER, ELECTRICAL having one or both ends processed and/or terminated in fittings which provide for connection to other items. Excludes CABLE AND CONDUIT ASSEMBLY, ELECTRICAL and items having branches or forks. See also WIRING HARNESS.20511150037Nuclear Warheads and Warhead Sections11350043Fuzing and Firing Devices, Nuclear Ordnance11900057Specialized Test and Handling Equipment, Nuclear Ordnance5995000061500055Miscellaneous Electric Power and Distribution Equipment

Part Alternates: A100548112, A1005481-12, NA5160572, NA5-16057-2, 6150-00-952-2677, 00-952-2677, 6150009522677, 009522677

Electric Wire, and Power and Distribution Equipment | Miscellaneous Electric Power and Distribution Equipment

Supply Group (FSG) NSN Assign. NIIN
61 04 MAY 1966 00-952-2677

Drawings & Photos | NSN 6150-00-952-2677


Cross Reference | NSN 6150-00-952-2677

Part Number Cage Code Manufacturer
A1005481-12 73293 L-3 COMMUNICATIONS ELECTRON TECHNOLOGIES, INC.
NA5-16057-2 94756 BOEING COMPANY, THE DBA BOEING

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6150-00-952-2677

Technical Data | NSN 6150-00-952-2677

Characteristic Specifications
CONDUCTOR QUANTITY 5
CONDUCTOR FORM STRANDED ALL CONDUCTORS
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS PLASTIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
ROUND CONDUCTOR SIZE 16 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR 19 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR 29 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY 5 SINGLES
VOLTAGE RATING 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
STYLE DESIGNATOR 34 INTERNAL ANGLE AND INTERNAL STRAIGHT CONNECTOR
OVERALL LENGTH 52.000 INCHES
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
CROSS SECTION OUTSIDE DIAMETER 0.750 INCHES NOMINAL
TERMINATION TYPE CONNECTOR PLUG BOTH ENDS ALL CONDUCTORS
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER 414-1530-129 1ST END ALL CONDUCTORS 414-1531-129 2ND END ALL CONDUCTORS
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE 94756 1ST END ALL CONDUCTORS 94756 2ND END ALL CONDUCTORS
III FSC APPLICATION DATA TEST SET GUIDED MISSILE
MANUFACTURERS CODE 73293
DESIGN CONTROL REFERENCE A1005481-12

Restrictions/Controls & Freight Information | NSN 6150-00-952-2677

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061130 CABLE ASSEMBLY
Less than car load rating Q 70
Less than truck load rating P 77.5
Water commodity Code 743 unknown
Originating Activity Code SU Ogden Air Logistics Center
Hill AFB, UT 84056-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6150-00-952-2677

Category Code Description
Materiel Management Aggregation CodeAHSU:LGM-30 MINUTEMAN
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplyFGZOgden Air Logistics Center
Hill AFB, UT 84056-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityTAF Recoverable Assembly Management System (AFRAMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each