NSN 6150-01-306-2943 DE10001, DE1-0001, 01-306-2943
Product Details | ELECTRICAL LOAD BANK
6150-01-306-2943 A set (bank) of electrical elements that are passive (resistive, inductive, capacitive) or active (motors, batteries). They are usually located adjacent to each other to form a consolidated set of any of these elements or any combination of them. A load bank is used to replace distributed or dispersed load elements contained in a power distribution system or electrical network for the purpose of providing a concentrated load. A load bank contains all the essential electrical characteristics necessary to terminate the circuit and functions in the same manner as the load which it is intended to replace. This description necessarily includes a bank of light bulbs or cone heating elements where energy conversion is primarily in the form of heat although visible radiant energy is the natural result of incandescent heating. Load banks are intended to cover a specific range of characteristics and normally operate at DC or at power frequencies 50, 60, or 400 Hz AC. Load banks may be uninstrumented or complete with integral instrumention and may also be furnished as skid or trailer mounted. Excludes TEST SET, ELECTRICAL (as modified). See also DUMMY LOAD, ELECTRICAL.
Part Alternates: DE10001, DE1-0001, 6150-01-306-2943, 01-306-2943, 6150013062943, 013062943
Electric Wire, and Power and Distribution Equipment | Miscellaneous Electric Power and Distribution Equipment
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | 22 AUG 1989 | 01-306-2943 | 33776 ( LOAD BANK, ELECTRICAL ) |
Cross Reference | NSN 6150-01-306-2943
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| DE1-0001 | 17023 | BRUCE AEROSPACE INC. DIV BRUCE AEROSPACE INC |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6150-01-306-2943
Technical Data | NSN 6150-01-306-2943
| Characteristic | Specifications |
|---|---|
| TEST TYPE FOR WHICH DESIGNED | COIL RESISTIVE POWER TEST |
| FREQUENCY RATING | 60.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM |
| INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
| SPECIAL FEATURES | POWER RATING 100.0 KILOWATTS AVERAGE; TERMINATION TYPE CONNECTOR RECEP-TACLE; COOLING METHOD FORCED AIR; OPERATING POSITION HORIZONTAL |
| TEST DATA DOCUMENT | 81349-MIL-D-82134B(MC) SPECIFICATION |
| MANUFACTURERS CODE | 17023 |
| DESIGN CONTROL REFERENCE | DE1-0001 |
Restrictions/Controls & Freight Information | NSN 6150-01-306-2943
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | N | The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 116030 | MACHINES ETC DATA PROCESSING |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | PA | Marine Corps Logistics Base Albany, GA 31704-1128 |
| Air Dimension Code | Z | Shipment is not a consolidation, but does exceed 72 inches in one or more dimensions. |
| Air Commodity | 2 | Arms/Weapons (all types including Inert Component Parts). When a 2 is indicated in the first position, then the special handling code must be determined from table 85 , part 1. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 4 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6150-01-306-2943
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 3 | Marine Corps Appropriation Stores Account Principal Item. |
| Combat Essentiality Code | 0 | Non-combat Essential End Item. End items that do not fit the definition of Code 1 items. |
| Materiel Management Code | 4 | Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665 |
| Echelon Management Code | 3 | Headquarters Marine Corps All Marine Corps-managed items managed by the ICP on a |
| Echelon Identification Code | A | Type 1 End Items 1 |
| Operational Test Code | 3 | All items requiring calibration. Items may be technical or non-technical in nature, (i.e., electronic test equipment, meters, gauges, torque wrenches, etc.) All OTC 3 items require established calibration procedures.BLANK |
| Physical Category Code | 1 | Bin |
| Source of Supply | MPB | Commanding General Marine Corps Logistics Command 566-2, Bldg. 3700 Albany, GA 31704-5000 |
| Agency | DM | U.S. Marine Corps |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |