Product Details | CONCENTRATED HEMODIALYSIS SOLUTION

6505-01-335-7402 A mixed concentrate of essential chemical substances for use, after dilution, in artificial kidney machines.

Part Alternates: SB1003, SB-1003, RENASOL, 6505-01-335-7402, 01-335-7402, 6505013357402, 013357402

Medical, Dental, and Veterinary Equipment and Supplies | Drugs and Biologicals

Supply Group (FSG) NSN Assign. NIIN
65 13 MAR 1991 01-335-7402

Cross Reference | NSN 6505-01-335-7402

Part Number Cage Code Manufacturer
RENASOL 0JG25 MEDIVATORS INC.
SB-1003 0JG25 MEDIVATORS INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6505-01-335-7402

Technical Data | NSN 6505-01-335-7402

Characteristic Specifications
ACTIVE MEDICAMENT MEDICINAL STRENGTH 139.000 MILLIEQUIVALENTS SODIUM PER LITER AND 3.500 MILLIEQUIVALENTS CALCIUM PER LITER AND 2.000 MILLIEQUIVALENTS POTASSIUM PER LITER AND 1.000 MILLIEQUIVALENTS MAGNESIUM PER LITER AND 106.500 MILLIEQUIVALENTS CHLORIDE PER LITER AND 200.000 MILLIGRAMS DEXTROSE PER LITER AND 35.000 MILLIEQUIVALENTS BICARBONATE PER LITER AND 4.000 MILLIEQUIVALENTS ACETATE PER LITER
ADMINISTRATION KIDNEY IRRIGATION
PRIMARY CONTAINER TYPE DRUM
PRIMARY CONTAINER CONTENT QUANTITY 55.000 GALLONS

Restrictions/Controls & Freight Information | NSN 6505-01-335-7402

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information