Product Details | MIDDLE EAR MIRROR

6515-01-139-8341 An item designed for use during surgical procedures on the middle ear.

Part Alternates: N1705 67, N170567, 6515-01-139-8341, 01-139-8341, 6515011398341, 011398341

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 07 OCT 1982 01-139-8341

Cross Reference | NSN 6515-01-139-8341

Part Number Cage Code Manufacturer
N1705 67 93180 BAUSCH & LOMB INCORPORATED DBA BAUSCH & LOMB

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-01-139-8341

Technical Data | NSN 6515-01-139-8341

Characteristic Specifications
DESIGN DESIGNATION HOUSE
MATERIAL AND LOCATION STEEL, CORROSION RESISTING OVERALL
SURFACE TREATMENT AND LOCATION CHROME PLATED OVERALL
SPECIFIC USE EAR
HANDLE SHAPE ROUND
OVERALL LENGTH 6.000 INCHES NOMINAL
OVERALL DIAMETER 2.0 MILLIMETERS NOMINAL
SPECIAL FEATURES PASSIVATED; 45 DEG ANGLE; ETCHED HANDLE
III PART NAME ASSIGNED BY CONTROLLING AGENCY MIRROR MIDDLE EAR HOUSE DESIGN 6" LG 45 DEG ANGLE PASSIVATED CRS

Restrictions/Controls & Freight Information | NSN 6515-01-139-8341

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 056680 DENTAL/MEDICAL/SURG INST R MACHINE
Less than car load rating
Less than truck load rating F 150.0
Water commodity Code 651 unknown
Originating Activity Code KX Defense Supply Center Philadelphia
Philiadelphia, PA 19101
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity M Medical supplies, equipment, samples records, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6515-01-139-8341

Category Code Description
Materiel Category and Inventory ManagerC Medical/Dental Materiel
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group03Not-Potency-Dated
Accounting Requirements CodeD Durable item. An item of Army property coded with an ARC of "D" in the AMDF. Durable items do not require property book accountability after issue from the stock record account, but do require hand receipt control when issued to the user. Commercial and fabricated items similar to items coded ?D?in the AMDF are considered durable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
Acquisition Advice CodesHDIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9LNavy-owned stocks of defense medical material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each