Product Details | ENDOBRONCHIAL TUBE

6515-01-258-9621 An elastic monoluminal or biluminal tube with balloon(s) and corresponding pilot bags. The forward section has one or more openings and may accomodate a spurlike appendix. It is used for endobronchial intubation, collapse therapy, or for draining the tracheobronchial system during lung surgery.

Part Alternates: 43161037, 43161-037, 6515-01-258-9621, 01-258-9621, 6515012589621, 012589621

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 10 JUL 1987 01-258-9621

Drawings & Photos | NSN 6515-01-258-9621


Cross Reference | NSN 6515-01-258-9621

Part Number Cage Code Manufacturer
43161-037 02318 BAXTER HEALTHCARE CORP BAXTER HOSPITAL SUPPLY DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-01-258-9621

Technical Data | NSN 6515-01-258-9621

Characteristic Specifications
DESIGN DESIGNATION BRONCHO-CATH
STYLE DESIGNATOR E12A TRACHEAL
NOMINAL DIAMETER 37.000 FRENCH
MATERIAL AND LOCATION PLASTIC, POLYVINYL CHLORIDE TUBE PLASTIC, POLYPROPYLENE CONNECTOR
INFLATION DEVICE PILOT BALLOON
TIP TYPE BALLOON
CORE FABRICATION METHOD NOT WOVEN
SPECIAL FEATURES DESIGNED W/LABELELED BRONCHIAL/TRACHEAL LUMENS/2-CUFFS SELF-SEALING VALVE; INCLUDED-BRONCHO-CATH TUBE; 3-GENTLE-FLOW SUCTION CATHETERS W/VACTROL CONNECTORS 2-RIGHT ANGLE ASSEMBLIES; 2-CONNECTORS; INDIVIDUALLY PACKED

Restrictions/Controls & Freight Information | NSN 6515-01-258-9621

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 056680 DENTAL/MEDICAL/SURG INST R MACHINE
Less than car load rating
Less than truck load rating F 150.0
Water commodity Code 534 unknown
Originating Activity Code KX Defense Supply Center Philadelphia
Philiadelphia, PA 19101
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity M Medical supplies, equipment, samples records, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable