NSN 6515-01-374-1397 A93A064, EDWARDS SWAN GANZ, EDWARDSSWANGANZ
Product Details | CARDIOVASCULAR CATHETER
6515-01-374-1397 A disposable item designed to be used either intra-arterially and/or intravenously for delivering radiopaque media to selected sites in the vascular system as in angiography.
Part Alternates: A93A064, EDWARDS SWAN GANZ, EDWARDSSWANGANZ, 744HF75 , 9321614LT, 93-2-16-14-LT , 93A-754H-7.5F, 93A754H75F, 6515-01-374-1397, 01-374-1397, 6515013741397, 013741397
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 17 APR 1993 | 01-374-1397 | 33294 ( CATHETER, CARDIOVASCULAR ) |
Cross Reference | NSN 6515-01-374-1397
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 744HF75 | 1PYT9 | EDWARDS LIFESCIENCES LLC |
| 93-2-16-14-LT | 66732 | DEPARTMENT OF THE ARMY U S ARMY MEDICAL MATERIAL AGENCY |
| 93A-754H-7.5F | 25074 | BAXTER HEALTHCARE CORP EDWARDS CRITICAL CARE DIV |
| A93A064 | 66732 | DEPARTMENT OF THE ARMY U S ARMY MEDICAL MATERIAL AGENCY |
| EDWARDS SWAN GANZ | 25074 | BAXTER HEALTHCARE CORP EDWARDS CRITICAL CARE DIV |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-01-374-1397
Related Products | NSN 6515-01-374-1397
Technical Data | NSN 6515-01-374-1397
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | D14 THERMODILUTION |
| NOMINAL DIAMETER | 7.500 FRENCH |
| CATHETER NOMINAL LENGTH | 110.0 CENTIMETERS |
| MATERIAL AND LOCATION | PLASTIC, POLYVINYL CHLORIDE OVERALL |
| CORE FABRICATION METHOD | ANY ACCEPTABLE |
| FEATURES PROVIDED | STERILE AND DISPOSABLE |
| SPECIAL FEATURES | LUMEN; ONE VOLUME-LIMITED SYRINGE; ONE IN VITRO OXIMETER CALIBRATOR; THERMODILUTION; VOLUMETRIC; OXIMETRY; 24 CM INJECTATE PORT; USED TO ASSESS PATIENT'S CONDITION THROUGH DIRECT INTRACARDIAC AND PULMONARY ARTERY PRESSURE MONITORING |
Restrictions/Controls & Freight Information | NSN 6515-01-374-1397
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||