NSN 6515-01-377-0463 F93D325 , 003760, 6000
Product Details | MEDICAL VENTILATOR CIRCUIT
6515-01-377-0463 A device designed for use in providing a conduit from a ventilator to a patient to provide necessary gases. May include pressure sensing line, temperature probe, and the like, see MANIFOLD ASSEMBLY, INHALATION THERAPY APPARATUS.
Part Alternates: F93D325 , 003760, 6000, 935142LT, 93-5-14-2-LT , 6515-01-377-0463, 01-377-0463, 6515013770463, 013770463
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 02 JUL 1993 | 01-377-0463 | 46873 ( CIRCUIT, VENTILATOR, MEDICAL ) |
Demand History | NSN 6515-01-377-0463
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 6000 | 2016-03-91 | 1 | US |
| 6000 | 2015-10-275 | 8 | United States |
| 6000 | 2012-11-313 | 2 | |
| 6000 | 2011-08-230 | 1 | |
| 6000 | 2010-07-201 | 1 | United States |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-01-377-0463
Related Products | NSN 6515-01-377-0463
Technical Data | NSN 6515-01-377-0463
| Characteristic | Specifications |
|---|---|
| UNIT PACKAGE QUANTITY | 15 |
| COMPONENT QUANTITY | 7 |
| NONSUPPLY ITEMS AND QUANTITIES | 90 DEGREE ELBOW; 1; 6 IN. AEROSOL TUBE; 1; EXHALATION VALVE W/DRIP CAMBER; 1; 72 IN. AEROSOL HOSE W/CUTTABLE CUFFS; 1; 71 IN. SUPPLY LINE; 1; 72 IN. PROXIMAL AIRWAY PRESSURE LINE; 1; PROXIMAL AIRWAY ADAPTER;1 |
| STERILITY | NONSTERILE |
| DISPOSITION AFTER INITIAL USE | DISPOSABLE |
| SPECIAL FEATURES | ADULT CIRCUIT USED ON THE PORTABLE VOLUME VENTILATOR FOR TRANSPORTING PATIENTS |
| III PART NAME ASSIGNED BY CONTROLLING AGENCY | CIRCUIT VENTILATOR MEDICAL 7 COMP ADL F/PRTBLE VOL VENTILATOR15S |
Restrictions/Controls & Freight Information | NSN 6515-01-377-0463
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | M | 24 months |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 056680 | DENTAL/MEDICAL/SURG INST R MACHINE |
| Less than car load rating | ||
| Less than truck load rating | F | 150.0 |
| Water commodity Code | 651 | unknown |
| Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | M | Medical supplies, equipment, samples records, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6515-01-377-0463
| Category | Code | Description |
|---|---|---|
| Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
| Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
| Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
| Specific Group/Generic Code | 0 | Medical Materiel |
| Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
| Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DA | Department of the Army |
| Service Organization | A | U.S. Army |
| Acquisition Advice Codes | L | LOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 PG : Package |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | L | LOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 PG : Package |



