Product Details | OXYGEN CONCENTRATOR

6515-01-461-1181 A portable instrument consisting of a calibrated illuminated flowmeter, built-in alarms for power failure and high/low pressure, filters to remove dust, bacteria, and other particulates, and also provides for the attachment of an in-line humidifier to humidify gas mixture delivered to the patient. It is designed for use in producing oxygen-rich gas mixture by drawing in room air and extracting oxygen.

Part Alternates: 49305100, 493051-00, 6515-01-461-1181, 01-461-1181, 6515014611181, 014611181

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 30 NOV 1998 01-461-1181

Cross Reference | NSN 6515-01-461-1181

Part Number Cage Code Manufacturer
493051-00 7Y988 NELLCOR PURITAN BENNETT INCORPORATED DBA COVIDIEN

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-01-461-1181

Technical Data | NSN 6515-01-461-1181

Characteristic Specifications
CURRENT TYPE AC
VOLTAGE IN VOLTS 240.0
FREQUENCY IN HERTZ 50.0
OVERALL LENGTH 645.0 MILLIMETERS NOMINAL
OVERALL WIDTH 317.5 MILLIMETERS NOMINAL
OVERALL HEIGHT 419.0 MILLIMETERS NOMINAL
SPECIAL FEATURES LOW PRESSURE ALARM; AUTOMATIC SHUT-DOWN WHEN A FAULT IS DETECTED IN THE SOLENOID CIRCUIT OR IF OXYGEN CONCENTRATION FALLS BELOW 70 PCT; GREEN LIGHT INDICATOR WHEN OXYGEN CONCENTRATION IS 85PCT OR ABOVE; YELLOW LIGHT INDICATOR WHEN OXYGEN IS BETWEEN 70 AND 85 PCT; RED LIGHT INDICATOR WHEN OXYGEN CONCENTRATION IS LESS THAN 70 PCT; AIR INLET FILTER; COMPRESSOR INLET PREFILTER AND INLET BACTERIA FILTER; GAS OUTLET FILTER

Restrictions/Controls & Freight Information | NSN 6515-01-461-1181

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information