NSN 6515-01-502-7075 SA-1A, SA1A, 01-502-7075
Product Details | SMOKE-FUM EVACUATOR
6515-01-502-7075
Part Alternates: SA-1A, SA1A, 6515-01-502-7075, 01-502-7075, 6515015027075, 015027075
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 18 NOV 2002 | 01-502-7075 | 77777 ( ) |
Cross Reference | NSN 6515-01-502-7075
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| SA-1A | 0V713 | SURG/ASSIST INC |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-01-502-7075
Related Products | NSN 6515-01-502-7075
Technical Data | NSN 6515-01-502-7075
| Characteristic | Specifications |
|---|---|
| MATERIAL | STEEL |
| SURFACE TREATMENT | PAINT |
| OVERALL LENGTH | 12.000 INCHES NOMINAL |
| OVERALL WIDTH | 11.000 INCHES NOMINAL |
| OVERALL HEIGHT | 10.000 INCHES NOMINAL |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 110.000 AC |
| CURRENT RATING | 6.000 AMPERES |
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | DETACHABLE HOSPITAL GRADE CORD;900 WATTS MAX POWER CONSUMPTION;20MM LONG X 5MM DIA FUSE;10 AMP QUICK-BLO FUSE;52.7 CFM AT 31.07 % EFFICIENCY MOTOR/BLOWER RATING;2.5CFM @ 5/16 IN TUBING TYPICAL AIRFLOW AT HOSE INTAKE;99.999% AT .2 MICRON PARTICULATE FILTRATION;ODOR FILTRATION ABSORPTION VIA ACTIVATED CHARCOAL; FILTER LONGEVITY APPROXIMATELY 30-45 MIN OF SMOKE SUCTION |
Restrictions/Controls & Freight Information | NSN 6515-01-502-7075
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||