NSN 6515-01-577-9586 OXIMAX N-65, OXIMAX N-65-NA1, OXIMAXN65
Product Details | PULSE OXIMETER
6515-01-577-9586 An item designed for use in monitoring oxygen saturation in the blood, pulse rate, saturated oxygen trend, and pulse amplitude. May include visual and audible alarms, preset alarm parameters, alarm silencer, reusable finger probes, and the like.
Part Alternates: OXIMAX N-65, OXIMAX N-65-NA1, OXIMAXN65, OXIMAXN65NA1, N65, N-65, 6515-01-577-9586, 01-577-9586, 6515015779586, 015779586
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 23 SEP 2009 | 01-577-9586 | 48302 ( OXIMETER, PULSE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-01-577-9586
Related Products | NSN 6515-01-577-9586
Technical Data | NSN 6515-01-577-9586
| Characteristic | Specifications |
|---|---|
| MOUNTING STAND | NOT PROVIDED |
| SPECIAL FEATURES | OXIMAX N-65-NA1 HANDHELD PULSE OXIMETER W/DURASENSOR DS-100A ADULT FINGER CLIP SENSOR, 1 YEAR WARRANTY; NONINVASIVE MEASUREMENT OF BLOOD OXYGEN SATURATION; 4 AA 19 HOUR BATTERIES; 0 TO 100 PCT DISPLAY RANGE; OXY SATURATION; PULSE RATE, VERTICAL BARGRAPH; OP TEMP P5/P 40 DEG C; DATA IN, LOW BATTERY SENSORS; PULSE AMPLITUDE AND SEARCH; LGTH 6.200 IN; WIDTH 2.800 IN; HT 1.400 IN; 6 VDC |
| CARRYING CASE | NOT PROVIDED |
| MATERIAL | PLASTIC |
| PORTABILITY | PORTABLE |
| DISPOSITION AFTER INITIAL USE | REUSABLE |
Restrictions/Controls & Freight Information | NSN 6515-01-577-9586
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||