Product Details | DENTURE TRIMMING BUR

6520-01-290-3262 An item used in the laboratory for cutting, grinding and contouring of all types of full and partial dentures.

Part Alternates: A-1/2, A12, 1878-09071, 9071, 6520-01-290-3262, 01-290-3262, 6520012903262, 187809071, 012903262

Medical, Dental, and Veterinary Equipment and Supplies | Dental Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 09 DEC 1988 01-290-3262

Cross Reference | NSN 6520-01-290-3262

Part Number Cage Code Manufacturer
1878-09071 1R993 DENTAL LABORATORY DISCOUNT SUPPLY
9071 63827 DEDECO INTERNATIONAL SALES, INC.
A-1/2 63827 DEDECO INTERNATIONAL SALES, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6520-01-290-3262

Technical Data | NSN 6520-01-290-3262

Characteristic Specifications
MATERIAL AND LOCATION TUNGSTEN CARBIDE HEAD AND STEEL, CORROSION RESISTING SHANK
OVERALL LENGTH 1.750 INCHES NOMINAL
SHANK DIAMETER 0.250 INCHES NOMINAL
HEAD SHAPE ROUNDED END AND TAPERED
HEAD LENGTH 1.000 INCHES
HEAD OVERALL DIAMETER 0.500 INCHES
SHANK OVERALL LENGTH 0.750 INCHES
SPECIAL FEATURES USED FOR REDUCTION OF METAL,MOLDS,PLASTIC AND PORCELAIN

Restrictions/Controls & Freight Information | NSN 6520-01-290-3262

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information

Management | NSN 6520-01-290-3262

Category Code Description
Cognizance Codes9LNavy-owned stocks of defense medical material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9MDefense Supply Center Philadelphia
Director of Medical Materiel
Philadelphia, PA 19145
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each