Product Details | IMPLAN SURGICAL KIT

6520-01-564-7108

Part Alternates: PSKT40, 6520-01-564-7108, 01-564-7108, 6520015647108, 015647108

Medical, Dental, and Veterinary Equipment and Supplies | Dental Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 25 JUN 2008 01-564-7108

Cross Reference | NSN 6520-01-564-7108

Part Number Cage Code Manufacturer
PSKT40 0H8C8 BIOMET 3I, LLC DBA 3 I IMPLANT INNOVATIONS
PSKT40 Z2A41 BIOMET AUSTRALIA PTY LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6520-01-564-7108

Technical Data | NSN 6520-01-564-7108

Characteristic Specifications
ACCESSORY COMPONENTS AND QUANTITY SURGICAL TRAY 1; 24MM TIP HEX DRIVER 1; HANDPIECE CONNECTOR 1; 17MM(L) SMALL HEX HAND DRIVER 1; 17MM(L) LARGE HEX HAND DRIVER 1; OPEN END WRENCH 1; RATCHET WRENCH 1; 6MM(L) SHORT RATCHET EXTENSION 1; 15MM(L) LONG RATCHET EXTENSION 1; IMPLANT DEPTH GAUGE 1; 15MM(L) MICROMINIPLANT MOUNT 1; 4MM(D) X 13MM(L) BONE TAP 1; 3.25MM(D) X 18MM(L) BONE TAP 1; 2MM(D) X 10MM(L) DIRECTIONAL INDICATOR 3; ROUND DRILL 1; REUSABLE TWIST DRILLS 12; 2-3MM(D) PILOT DRILL 1; COUNTERSINK DRILL 1; DRILL EXTENSION 1; ORGANIZER TRAY 1
SPECIAL FEATURES SURGICAL KIT, WITH PARALLEL WALLED SURGICAL IMPLANT PLACEMENT
III PART NAME ASSIGNED BY CONTROLLING AGENCY PREMIUM KIT FOR EXTERNAL HEX, INTERNAL HEX IMPLANTS

Restrictions/Controls & Freight Information | NSN 6520-01-564-7108

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information