| Characteristic | Specifications |
|---|---|
| DESIGN TYPE | STATIONARY |
| TUBE TYPE | DOUBLE FOCUS, ROTATING ANODE RADIOGRAPHIC AND DOUBLE FOCUS, ROTATING ANODE FLUOROSCOPIC |
| TUBE QUANTITY | 1 AND 1 |
| TUBE COOLING METHOD | AIR AND AIR |
| TUBE MOUNTING TYPE | TUBE STAND AND TABLE |
| TUBE STAND MOUNTING TYPE | FLOOR TO CEILING |
| FLOOR TO CEILING HEIGHT RANGE | 9.000 TO 10.500 FEET |
| TABLE TYPE | TILTING |
| TILT RANGE | 90 DEG TRENDELENBURG TO VERTICAL |
| DRIVE TYPE | MOTOR |
| BUCKY DIAPHRAGM | INCLUDED |
| CONTROL TYPE | CABINET |
| MOUNTING TYPE | STATIONARY |
| OPERATION METHOD | AUTOMATIC |
| RADIOGRAPHIC TIMER TYPE | EXPOSURE |
| FLUOROSCOPIC TIMER TYPE | SYNCHRONOUS MOTOR |
| TRANSFORMER RECTIFICATION METHOD | ELECTRON TUBE |
| RECTIFICATION TYPE | FULL-WAVE |
| TRANSFORMER OUTPUT CAPACITY | 300 MA AT 125 KV PEAK AND 10 MA AT 140 KV P-AK |
| FLUOROSCOPIC SCREEN TYPE | ANY ACCEPTABLE |
| SCREEN LENGTH | 12.000 INCHES NOMINAL |
| SCREEN WIDTH | 12.000 INCHES NOMINAL |
| SCREEN TYPE | W/SPOT-FILM |
| CASSETTE SIZE | 8 INCH BY 10 INCH; 10 INCH BY 12 INCH |
| VOLTAGE IN VOLTS | 220.0 |
| CURRENT RATING IN AMPS | 200.0 |
| FREQUENCY IN HERTZ | 60.0 |
| PHASE | SINGLE |
| ELECTRIC POWER RATING | 40000.0 WATTS NOMINAL |
| ACCESSORY COMPONENTS AND QUANTITY | COLLIMATOR 1,COMPRESSION DEVICE 1,FOOTREST 1,ADJUSTABLE PATIENT GRASP HANLDE 2,TABLE TILT INDICATOR 1,PHOTO-TIMER /OPTIONAL/ 1,RADIATION SHIELD 1,SUPPORT SHOULDER 1 |
| SPECIAL FEATURES | C/O CONTROL UNIT,TRANSFORMER,COLLIMATOR,90 DEG TRENDELENBURG (90/90 DEG) TILT TABLE,SPOT FILM DEVICE,BUCKY DIAPHRAM,OVER HEAD TUBE MOUNT; NOT FOR FIELD USE; 9-1/2 BY 9-1/2 IN. FRONT-END-LOADING,REQUISITION SHOULD STATE WHETHER CASSETTE CHANGER IS REQUIRED,WHETHER PHOTO TIMERS FOR BUCKY AND CASSETTE CHANGER ARE REQUIRED |
| III SUPPLEMENTARY FEATURES | REQUISITION SHOULD STATE FLOOR-LOADING CAPACITY,CEILING STRENGTH AND HEIGHT,WALL AND FLOOR CONSTRUCTION (CONCRETE,WOOD ETC),ELECTRICAL SUPPLY AND CAPACITY,DIAGRAM OF ROOM INDICATING DIMENSIONS,COMPATABILITY W/EXISTING FACILITIES,AND WHETHER OR NOT CONTRACTOR INSTALLATION |
Restrictions/Controls & Freight Information | NSN 6525-00-082-2692
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||