Product Details | DENTAL X-RAY APPARATUS

6525-00-222-1340 00001016525000000

Part Alternates: 2411, 6525-00-222-1340, 00-222-1340, 6525002221340, 002221340

Medical, Dental, and Veterinary Equipment and Supplies | X-ray Equipment and Supplies: Medical, Dental, Veterinary

Supply Group (FSG) NSN Assign. NIIN
65 01 JUL 1969 00-222-1340

Cross Reference | NSN 6525-00-222-1340

Part Number Cage Code Manufacturer
2411 79555 PENNWALT CORP S S WHITE DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6525-00-222-1340

Technical Data | NSN 6525-00-222-1340

Characteristic Specifications
DESIGN TYPE STATIONARY
TUBE TYPE LINE FOCUS
TUBE QUANTITY 1
TUBE COOLING METHOD OIL
TUBE MOUNTING TYPE TUBE STAND
TUBE STAND MOUNTING TYPE BASE
CONTROL TYPE CABINET
MOUNTING TYPE WALL
OPERATION METHOD AUTOMATIC
RADIOGRAPHIC TIMER TYPE EXPOSURE
TRANSFORMER RECTIFICATION METHOD SELF-RECTIFYING
RECTIFICATION TYPE HALF-WAVE
TRANSFORMER OUTPUT CAPACITY 10.0 OUTPUT MA AT 90 KV PEAK
VOLTAGE IN VOLTS 110.0 AND 125.0
CURRENT RATING IN AMPS 10.0
FREQUENCY IN HERTZ 50.0 OR 60.0
PHASE SINGLE
ELECTRIC POWER RATING 2400.0 WATTS NOMINAL
ACCESSORY COMPONENTS AND QUANTITY CASSETTE 1; FILM PROCESSING HANGARS 3; HEAD MEASURING CALIPERS 1; INTRA-ORAL MIDLINE LOCATORS 2
SPECIAL FEATURES FOR REPLACEMENT CASSETTE ORDER 6525-00-222-1341; FOR REPLACEMENT TUBE TRANSFORMER HEAD ORDER 6525-00-222-1347
III SUPPLEMENTARY FEATURES PATIENTS HEAD CONCENTRENTIC POSITIONER; PANOGRAPHIC; MOTOR DRIVEN CHAIR
III EXTERIOR CONTAINER QUANTITY 1
III UNIT OF ISSUE WEIGHT 0.05 POUNDS
III EXTERIOR CONTAINER WEIGHT 766.00 POUNDS
III UNIT OF ISSUE CUBE 0.001 CUBIC FEET
III EXTERIOR CONTAINER CUBIC MEASURE 89.00 CUBIC FEET

Restrictions/Controls & Freight Information | NSN 6525-00-222-1340

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063560 X-RAY MACHINE SUB 1
Less than car load rating J 100.2
Less than truck load rating J 100.2
Water commodity Code 656 unknown
Originating Activity Code KX Defense Supply Center Philadelphia
Philiadelphia, PA 19101
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity M Medical supplies, equipment, samples records, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6525-00-222-1340

Category Code Description
Materiel Category and Inventory ManagerC Medical/Dental Materiel
Appropriation and Budget ActivityQ Other Support Equipment
Management Inventory Segment1 REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group03Not-Potency-Dated
Accounting Requirements CodeN Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items.
Source of SupplyS9MDefense Supply Center Philadelphia
Director of Medical Materiel
Philadelphia, PA 19145
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityFIf condemned or uneconomically repairable, then dispose at Direct Support (DS) level.
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9LNavy-owned stocks of defense medical material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9MDefense Supply Center Philadelphia
Director of Medical Materiel
Philadelphia, PA 19145
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each