NSN 6525-00-601-4500 MILD15862TYPE3, 00-601-4500, 006014500
Product Details | X-RAY FILM DRIER
6525-00-601-4500 A device designed for removing moisture from X-ray film either by absorbent chemicals, air currents, heat, or combinations.20265250059Imaging Equipment and Supplies: Medical, Dental, Veterinary66350042Physical Properties Testing and Inspection
Part Alternates: MILD15862TYPE3, 6525-00-601-4500, 00-601-4500, 6525006014500, 006014500
Medical, Dental, and Veterinary Equipment and Supplies | X-ray Equipment and Supplies: Medical, Dental, Veterinary
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 01 JAN 1963 | 00-601-4500 | 14729 ( DRIER, X-RAY FILM ) |
Cross Reference | NSN 6525-00-601-4500
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MILD15862TYPE3 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6525-00-601-4500
Related Products | NSN 6525-00-601-4500
Technical Data | NSN 6525-00-601-4500
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 2.583 FEET NOMINAL |
| OVERALL WIDTH | 2.583 FEET NOMINAL |
| OVERALL HEIGHT | 7.000 FEET NOMINAL |
| UNIT TYPE | STATIONARY |
| HEATER TYPE | STRIP |
| HEATER QUANTITY | 2 |
| WATTAGE RATING IN WATTS | 1250.0 |
| HEATING ELEMENT VOLTAGE RATING | 110.0 |
| DRAWER QUANTITY | 2 |
| FILM HANGER QUANTITY ACCOMMODATED PER DRAWER | 12 |
| SUSPENSION TYPE | PROGRESSIVE |
| EXHAUST FAN LOCATION | TOP |
| AIR CAPACITY | 500.000 CUBIC FEET PER MINUTE |
| SWITCH TYPE | TOGGLE |
| SWITCH QUANTITY | 2 |
| COUNTERSUNK FEATURE | NOT INCLUDED |
| IDENTIFIED SWITCH | PROVIDED |
| HEATER INTERLOCKED W/FAN FEATURE | INCLUDED |
| CURRENT TYPE | AC |
| VOLTAGE IN VOLTS | 110.0 |
| FREQUENCY IN HERTZ | 60.0 |
| ACCESSORY COMPONENTS AND QUANTITY | NOT APPLICABLE |
| AUTOMATIC TIMER | NOT INCLUDED |
| MOUNTING TYPE | FLOOR |
| SPECIAL FEATURES | 14 IN. BY 17 IN. SIZE FILM ACCOMMODATED |
| NONDEFINITIVE SPEC/STD DATA | 3 TYPE |
| MANUFACTURERS CODE | 81349 |
| DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MILD15862TYPE3 |
Restrictions/Controls & Freight Information | NSN 6525-00-601-4500
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||
Management | NSN 6525-00-601-4500
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | S9M | Defense Supply Center Philadelphia Director of Medical Materiel Philadelphia, PA 19145 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |