NSN 6525-01-150-2943 S96310, S-96310, 01-150-2943
Product Details | X-RAY SYSTEM CALIBRATOR HIGH VOLTAGE DIVIDER UNIT
6525-01-150-2943 An item which, when interfaced with a CALIBRATOR SET, X-RAY SYSTEM, affords invasive compliance testing capabilities in accordance with regulations governing stationary radiographic and fluoroscopic x-ray systems. It is designed primarily to convert x-ray generator peak kilovoltage, milliamperes, and/or x-ray tube filament current to low voltage signals which may be monitored by external equipment. It may have the capability to analyze and/or troubleshoot system problems when interfaced with certain operating components supplied separately or already present at the point of usage.
Part Alternates: S96310, S-96310, 6525-01-150-2943, 01-150-2943, 6525011502943, 011502943
Medical, Dental, and Veterinary Equipment and Supplies | X-ray Equipment and Supplies: Medical, Dental, Veterinary
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 02 APR 1983 | 01-150-2943 | 41727 ( HIGH VOLTAGE DIVIDER UNIT, X-RAY SYSTEM CALIBRATOR SET ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6525-01-150-2943
Technical Data | NSN 6525-01-150-2943
| Characteristic | Specifications |
|---|---|
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | REPLACEMENT UNIT FOR CALIBRATOR SET,6525-01-151-6400; CONVERTS X-RAY GENERATOR HIGH TENSION KVP,MA AND X-RAY TUBE FILAMENT CURRENTS TO LOW VOLTAGE SHOCKPROOF SIGNALS; HIGH VOLTAGE DIVIDER NETWORK PROVIDES FREQUENCY RESPONSE OF PORM 1DB FROM 0 TO 100 KHZ; ANODE CURRENT SENSOR PROVIDES AN ISOLATED SIGNAL REPRESENTING ANODE WAVEFORM AND MEASURES CURRENT W/I RANGE OF 1 MA TO 2 AMPERES W/2 PCT ACCURACY FOR GREATER THAN 10 MA; X-RAY TUBE FILAMENT CURRENT MONIOR MEASURES CURRENTS UP TO 20 AMPERES W/ACCURACY OF PORM 1 PCT AT 60 HZ; 2 5 FT CABLES; OPERATES ON 115/230 VOLTS,50/60 HZ,AC; W/CARRYING CASE; FOR REPLACEMENT CABLE USE 6525-01-076-4716 |
| III EXTERIOR CONTAINER QUANTITY | 1 |
| III UNIT OF ISSUE WEIGHT | 45.00 POUNDS |
| III EXTERIOR CONTAINER WEIGHT | 45.00 POUNDS |
| III UNIT OF ISSUE CUBE | 4.10 CUBIC FEET |
| III EXTERIOR CONTAINER CUBIC MEASURE | 4.10 CUBIC FEET |
| III PART NAME ASSIGNED BY CONTROLLING AGENCY | HIGH VOLTAGE DIVIDER UNIT X-RAY SYS CAL SET 115/230V50-60HZ AC |
Restrictions/Controls & Freight Information | NSN 6525-01-150-2943
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||
Management | NSN 6525-01-150-2943
| Category | Code | Description |
|---|---|---|
| Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
| Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
| Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
| Specific Group/Generic Code | 0 | Medical Materiel |
| Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
| Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DA | Department of the Army |
| Service Organization | A | U.S. Army |
| Acquisition Advice Codes | A | SERVICE/AGENCY-REGULATED (Service/Agency use only.) # Issue, transfer or shipment is controlled by authorities above the ICP level to assure proper and equitable distribution. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | L | LOCAL PURCHASE # (NON-STOCKED ITEMS) Defense Logistics Agency (DLA)/GSA/Service/Agency-managed items authorized for local purchase as normal means of support at base, post, camp or station level. Item not stocked in wholesale distribution system of IMM/Service/Agency ICP. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |