Product Details | X-RAY TUBE

6525-01-578-6216 A vacuum tube containing electrodes that accelerate electrons and directs them to a metal anode, where their impact produces X-rays.20265250059Imaging Equipment and Supplies: Medical, Dental, Veterinary66350042Physical Properties Testing and Inspection

Part Alternates: D3142T, 6525-01-578-6216, 01-578-6216, 6525015786216, 015786216

Medical, Dental, and Veterinary Equipment and Supplies | X-ray Equipment and Supplies: Medical, Dental, Veterinary

Supply Group (FSG) NSN Assign. NIIN
65 14 OCT 2009 01-578-6216

Demand History | NSN 6525-01-578-6216

Part Number Request Date QTY Origin
6525-01-578-6216 2014-02-56 1 US
6525-01-578-6216 2014-01-08 1 KR
D3142T 2013-10-289 1 US

Cross Reference | NSN 6525-01-578-6216

Part Number Cage Code Manufacturer
D3142T 0U5H8 INSTRUMENTARIUM IMAGING INC DBA FOREIGN PARENT IS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6525-01-578-6216

Technical Data | NSN 6525-01-578-6216

Characteristic Specifications
SPECIAL FEATURES BRAZED GRAPHITE DESIGN,FOCAL SPOT SIZE 0.9MM WIDTH X 0.52MM LENGTH AND 1.2MM WIDTH X 1.2MM LENGTH,TARGET ANGLE 7DEGREES,8400MIN ROTOR SPEED,HEAT STORAGE CAPACITY ANODE 3500KHU,TUBE UNIT 3700KHU,INTERNAL DIRECTED OIL CIRCULATION,EXTERNAL OIL TO AIR HEAT EXCHANGER,OFF POWER PRESSURE SWITCH MOUNTED IN TUBE,LEAKAGE TECHNIQUE FACTOR IS 140KVP,26MA,INHERENT FILTRATION IS 1.2MM AT 140KV,TUBE INSERT 0.8MM ALUMINUM EQUIVALENT AT 140KV,TUBE HOUSING 0.4MM ALUMINUM EQUIVALENT AT 140KV
MATERIAL ALUMINUM AND CERAMIC AND LEAD

Restrictions/Controls & Freight Information | NSN 6525-01-578-6216

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information