NSN 6530-00-065-5242 GGS001340, 00-065-5242, 000655242
Product Details | SURGICAL DRESSING STERILIZER
6530-00-065-5242 00001016530000000
Part Alternates: GGS001340, 6530-00-065-5242, 00-065-5242, 6530000655242, 000655242
Medical, Dental, and Veterinary Equipment and Supplies | Hospital Furniture, Equipment, Utensils, and Supplies
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 01 JAN 1963 | 00-065-5242 | 04494 ( STERILIZER, SURGICAL DRESSING0 ) |
Cross Reference | NSN 6530-00-065-5242
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| GGS001340 | 81348 | FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6530-00-065-5242
Related Products | NSN 6530-00-065-5242
Technical Data | NSN 6530-00-065-5242
| Characteristic | Specifications |
|---|---|
| CURRENT TYPE | AC |
| VOLTAGE RATING | 115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
| HEAT TRANSFER METHOD | PRESSURE STEAM |
| HEATING METHOD | STEAM FROM REMOTE STEAM SOURCE |
| OVERALL HEIGHT | 70.000 INCHES MINIMUM AND 75.000 INCHES MAXIMUM |
| OVERALL LENGTH | 44.000 INCHES NOMINAL |
| OVERALL WIDTH | 26.000 INCHES NOMINAL |
| MATERIAL | NICKEL OR NICKEL COPPER ALLOY AND STEEL, CORROSION RESISTING |
| CLOSURE METHOD | HINGED DOOR SECURED BY LOCKING LEVERS |
| MOUNTING TYPE | CABINET |
| INSIDE WIDTH | 16.000 INCHES NOMINAL |
| INSIDE LENGTH | 26.000 INCHES NOMINAL |
| INSIDE HEIGHT | 16.000 INCHES NOMINAL |
| ACCESSORY COMPONENTS AND QUANTITY | TRAY,INSTRUMENT 1,SHELF,BOTTOM 1 |
| SPECIAL FEATURES | HANDWHEEL OPERATED |
| NONDEFINITIVE SPEC/STD DATA | 1 TYPE AND 1 SIZE AND 1 STYLE |
| MANUFACTURERS CODE | 81348 |
| NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | GGS001340 |
Restrictions/Controls & Freight Information | NSN 6530-00-065-5242
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 179320 | STERILIZERS NOI |
| Less than car load rating | J | 100.2 |
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 534 | unknown |
| Originating Activity Code | XX | |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | M | Medical supplies, equipment, samples records, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6530-00-065-5242
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | S9M | Defense Supply Center Philadelphia Director of Medical Materiel Philadelphia, PA 19145 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |