NSN 6530-00-149-0126 M0X100TM, 00-149-0126, 001490126
Product Details | KIDNEY PRESERVATION SYSTEM
6530-00-149-0126 An item designed for use in maintaining viability of kidney(s) while they are being transported between medical facilities and for the preservation of renal organs prior to transportation. The item may be portable, battery or line powered and can be used with mobile preservation system.
Part Alternates: M0X100TM, 6530-00-149-0126, 00-149-0126, 6530001490126, 001490126
Medical, Dental, and Veterinary Equipment and Supplies | Hospital Furniture, Equipment, Utensils, and Supplies
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 31 OCT 1973 | 00-149-0126 | 47748 ( PRESERVATION SYSTEM, KIDNEY ) |
Cross Reference | NSN 6530-00-149-0126
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| M0X100TM | 14499 | ZAREBA SYSTEMS INC. DIV WATERS MEDICAL SYSTEMS/ZAREBA |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6530-00-149-0126
Related Products | NSN 6530-00-149-0126
Technical Data | NSN 6530-00-149-0126
| Characteristic | Specifications |
|---|---|
| SPECIAL FEATURES | PORTABLE; BATTERY OR POWERED; 12 VOLT DC OR 115 VOLT,60 HZ,AC; 150 WATTS; OVERALL DIMENSIONS: 21 BY 17 BY 13 INCHES; INSULATED ALUMINUM CABINET; WITH A STERILE,DISPOSABLE,PLASTIC ORGAN CASSETTE WHICH INCLUDES A COMLETE CIRCULATION SYSTEM WITH ORGAN CHAMBERS TO ACCOMODATE ONE OR TWO KIDNEYS; AND A SET OF TWO EACH SIZE 2 THROUGH 7 MM CANNULAS; INCLUDES TEMPERATURE CONTROL SYSTEM,OXYGEN AND CARBON DIOXIDE REGULATOR; ICE CHEST,SWITCHES FOR MASTER POWER,PULSATILE PUMP,COOLANT CIRCULATING PUMP,RECHARGEABLE POWER PACK AND FOUR POSITION POWER SELECTOR SWITCH FOR BATTERY OPERATION OR TO RECHARGE BATTERY,AC OPERATION,AIRCRAFT OPERATION (400 HZ),OR AUXILIARY POWER SUPPLY (CIGARETTE LIGHTER); ORGAN CASSETTE MAY BE USED W/MOBILE PRESERVATION SYSTEM,6530-00-149-0125; FOR IN-HOSPITAL OPER. FOR USE IN MAINTAINING THE VIABILITY OF KIDNEY(S) DURING TRANSPORTATION PRIOR TO TRANSPLANTATION |
| III EXTERIOR CONTAINER QUANTITY | 1 |
| III UNIT OF ISSUE WEIGHT | 86.0000 POUNDS |
| III EXTERIOR CONTAINER WEIGHT | 86.00 POUNDS |
| III UNIT OF ISSUE CUBE | 9.4656 CUBIC FEET |
| III EXTERIOR CONTAINER CUBIC MEASURE | 9.465 CUBIC FEET |
Restrictions/Controls & Freight Information | NSN 6530-00-149-0126
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||
Management | NSN 6530-00-149-0126
| Category | Code | Description |
|---|---|---|
| Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
| Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
| Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
| Specific Group/Generic Code | 0 | Medical Materiel |
| Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
| Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
| Source of Supply | S9M | Defense Supply Center Philadelphia Director of Medical Materiel Philadelphia, PA 19145 |
| Agency | DA | Department of the Army |
| Service Organization | A | U.S. Army |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | JDC | |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |