NSN 6530-01-246-0119 MTA4707, 01-246-0119, 012460119
Product Details | PATIENT THERMOREGULATOR
6530-01-246-0119 An item designed to lower or raise the body temperature of the patient during surgery, as well as quickly reducing and controlling dangerously high temperatures of postoperative infections. Temperature readings can be made esophageally or rectally by the use of thermistor sensing probes.
Part Alternates: MTA4707, 6530-01-246-0119, 01-246-0119, 6530012460119, 012460119
Medical, Dental, and Veterinary Equipment and Supplies | Hospital Furniture, Equipment, Utensils, and Supplies
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 08 DEC 1986 | 01-246-0119 | 28787 ( THERMOREGULATOR, PATIENT ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6530-01-246-0119
Related Products | NSN 6530-01-246-0119
Technical Data | NSN 6530-01-246-0119
| Characteristic | Specifications |
|---|---|
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | AUTOMATIC AND MANUALLY OPERATED; 120/230 VOLT,50/60 HZ,AC,SOLID STATE,1150 WATTS; MOUNTED ON CASTORS OR MOBILE STAND; C/O ELECTRICAL TEMP CONTROL,FLUID CONTROL AND REFRIGERATION SYSTEM; W/3 MODES: AUTOMATIC MODE MONITORS PATIENT'S TEMP AND HEATS OR COOLS PATIENT TO PRESET TEMP; MANUAL MODE CONTROLS FLUID TEMP GOING TO BLANKET; AND MONITORING MODE INDICATES PATIENT TEMP ONLY; WILL NOT HEAT,COOL OR CIRCULATE FLUID; VISUAL DISPLAY; 14 BLANKETS,6 SIZES,AT LEAST 2 BLANKETS OF EACH SIZE; 1 ESOPHAGEAL/ RECTAL PROBE; DRAIN TUBING; 1 PAD; EXTENSION TUBING; DEPLOYABLE MEDICAL ITEM; ELECTRICAL CHARACTERISTICS AND PROVISIONING |
| III PART NAME ASSIGNED BY CONTROLLING AGENCY | THERMOREGULATOR PATIENT120/230V50/60HZ AC SS1150WATTS DEPMEDS |
Restrictions/Controls & Freight Information | NSN 6530-01-246-0119
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 188340 | VALVES THEMOSTATIC NOI/THEMOSTATS |
| Less than car load rating | ||
| Less than truck load rating | J | 100.2 |
| Water commodity Code | 651 | unknown |
| Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | M | Medical supplies, equipment, samples records, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6530-01-246-0119
| Category | Code | Description |
|---|---|---|
| Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
| Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
| Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
| Specific Group/Generic Code | 0 | Medical Materiel |
| Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
| Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DA | Department of the Army |
| Service Organization | A | U.S. Army |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |