Product Details | SURGICAL INSTRUMENT AND DRESSING STERILIZER

6530-01-442-8720 00001016530000000

Part Alternates: 000482, 00-0482, 265560, MC10, 6530-01-442-8720, 01-442-8720, 6530014428720, 014428720

Medical, Dental, and Veterinary Equipment and Supplies | Hospital Furniture, Equipment, Utensils, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 01-442-8720

Cross Reference | NSN 6530-01-442-8720

Part Number Cage Code Manufacturer
265595 05852 BARNSTEAD THERMOLYNE CORPORATION DBA BARNSTEAD INTERNATIONAL DIV
96-0491 89875 DEFENSE LOGISTICS AGENCY DIRECTORATE OF MEDICAL MATERIEL
MC8 05852 BARNSTEAD THERMOLYNE CORPORATION DBA BARNSTEAD INTERNATIONAL DIV
SP0200-96-C-8518 05852 BARNSTEAD THERMOLYNE CORPORATION DBA BARNSTEAD INTERNATIONAL DIV
ST75925 22527 FISHER SCIENTIFIC COMPANY L.L.C.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6530-01-442-8720

Technical Data | NSN 6530-01-442-8720

Characteristic Specifications
CURRENT TYPE AC
VOLTAGE RATING 120.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL
HEAT TRANSFER METHOD PRESSURE STEAM
HEATING METHOD ELECTRICAL
OVERALL HEIGHT 18.000 INCHES MAXIMUM
OVERALL LENGTH 24.000 INCHES MAXIMUM
OVERALL WIDTH 20.000 INCHES MAXIMUM
MATERIAL METAL, CORROSION RESISTING
INSIDE LENGTH 15.500 INCHES NOMINAL
INSIDE DIAMETER 8.000 INCHES MINIMUM AND 10.000 INCHES MAXIMUM
ACCESSORY COMPONENTS AND QUANTITY REMOVABLE TRAY AND RACK, 1 EA; REUSABLE CONTAINER, 1 EA; SERVICE MANUAL, 2 EA; OPERATING/INSTRUCTION MANUAL, 2 EA.
SPECIAL FEATURES A PORTABLE, AUTOMATICALLY CONTROLLED, HIGH SPEED, SINGLE SHELL, ENCASED IN A CABINET STERILIZER. C/O: A CABINET, STERILIZING CHAMBER, WATER RESERVOIR, ELECTRIC HEATER, SYSTEM CONTROLS AND VALVES. ATTAINS AND MAINTAINS A TEMP OF 270 DEG F FOR 5 MINUTES AND 250 DEG F FOR 20 MINUTES. WITHSTANDS A MINIMUM CHAMBER OF 60 PSI AND INCLUDES A SAFETY VALVE SET AT A PRESSURE BETWEEN 35 AND 45 PSI. THE RESERVOIR IS COMPLETELY ENCLOSED WITHIN THE CABINET AND HOLDS A SUFFCIENT AMOUNT OF WATER FOR 10 STERILIZATION CYCLES. THE FILL OPENING IS LOCATED ON TOP OF THE CABINET AND IS SUPPLIED WITH A COVER TO PREVENT INADVERTENT SPILLAGE. HAS THE FOLLOWING OPERATING CONTROLS: TEMP CONTROLLER/INDICATOR, CYCLE TIMER, HEATING LIGHT, TIMING LIGHT AND A DRYING LIGHT.
III SUPPLEMENTARY FEATURES USED FOR STERILIZING DENTAL AND SURGICAL INSTUMENTS AND DRESSINGS IN MILITARY FIELD MEDICAL FACILITIES.
III PART NAME ASSIGNED BY CONTROLLING AGENCY STERILIZER SURGICAL INSTRUMENT AND DRESSING120/230V

Restrictions/Controls & Freight Information | NSN 6530-01-442-8720

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Category Code Description
No Freight Information