NSN 6550-01-600-8845 558450, 01-600-8845, 016008845
Product Details | HUMAN IL-13 FLEX SET
6550-01-600-8845
Part Alternates: 558450, 6550-01-600-8845, 01-600-8845, 6550016008845, 016008845
Medical, Dental, and Veterinary Equipment and Supplies | In Vitro Diagnostic Substances, Reagents, Test Kits and Sets
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 65 | 27 DEC 2011 | 01-600-8845 | 77777 ( ) |
Cross Reference | NSN 6550-01-600-8845
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 558450 | 0GKS0 | BECTON, DICKINSON AND COMPANY DBA BD BIOSCIENCES |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6550-01-600-8845
Related Products | NSN 6550-01-600-8845
Technical Data | NSN 6550-01-600-8845
| Characteristic | Specifications |
|---|---|
| END ITEM IDENTIFICATION | BD CYTOMETRIC BEAD ARRAY (CBA) |
| SPECIAL FEATURES | CONTAINS HUMAN IL-13 STANDARD, HUMAN IL-13 CAPTURE BEAD E6, AND HUMAN IL-13 PE DETECTION REAGENT. BEAD-BASED IMMUNASSAY CAPABLE OF MEASURING HUMAN INTERLEUKIN- 13 IN SERUM, PLASMA, AND CELLCULTURE SUPERNATANT SAMPLES. SET CONTINS ONE VIAL EACH OF CAPTURE BEAD AND PE DETECTION REAGENT AND TWO VIALS OF STANDARD. CAPTURE BEAD AND PE DETECTION REAGENT COMPONENTS HAVE BEEN FORMULATED TO A 50X CONCENTRATION TO ENSURE PRODUCT PERFORMANCE WHEN MULTIPLESED. WHEN RECONSTITUTED IN 4.0 ML ASSAY DILUENT, THE STANDARD HAS A PROTIEN CINCENTRATION OF 2,500 PG/ML. DISCARD UNUSED RECONSTITUTED STANDARD, DO NOT STOR OR REUSE. STORE LYPHILIZED STANDARD AND OTHER COMPONENTS AT 4 DEGREES C. PROTECT PE DETECTION REAGENT FROM PROLOGED EXPOSURE TO LIGHT. |
Restrictions/Controls & Freight Information | NSN 6550-01-600-8845
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||



