Product Details | GYROSCOPE ASSEMBLY

6605-00-239-8656

Part Alternates: 6597302, 659730-2, 6605-00-239-8656, 00-239-8656, 6605002398656, 002398656

Instruments and Laboratory Equipment | Navigational Instruments

Supply Group (FSG) NSN Assign. NIIN
66 30 DEC 1971 00-239-8656

Cross Reference | NSN 6605-00-239-8656

Part Number Cage Code Manufacturer
659730-2 06481 NORTHROP GRUMMAN SYSTEMS CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6605-00-239-8656

Technical Data | NSN 6605-00-239-8656

Characteristic Specifications
GENERAL CHARACTERISTICS ITEM DESCRIPTION TORQUER CIRCUITS STABILIZED BY APPLYING 3 TIMES TO EACH TORQUER AXIS 0.180 TO 0.220 AMPS RMS 60 HZ FOR 0.10 TO 0.20 SECONDS
MANUFACTURERS CODE 06481
DESIGN CONTROL REFERENCE 659730-2

Restrictions/Controls & Freight Information | NSN 6605-00-239-8656

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:NThe item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information

Management | NSN 6605-00-239-8656

Category Code Description
Cognizance Codes7RAeronautical Depot Level Repairable Spares
Naval Inventory Control Point, Philadelphia
Special Material IDYX
Issue Repair, or RequisitionBSSubmit/refer requisitions to NAVICP PHIL.
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityHDepot Level Reparable
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative