Product Details | RADIO FREQUENCY POWER TEST SET

6625-00-229-1038 A test set primarily designed for use in making examinations of the power output of radio frequency oscillators and radio and radar transmitters. See also TEST SET, ELECTRICAL POWER; and WATTMETER.20211900057Specialized Test and Handling Equipment, Nuclear Ordnance66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: TS125AP, 6625-00-229-1038, 00-229-1038, 6625002291038, 002291038

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1963 00-229-1038

Cross Reference | NSN 6625-00-229-1038

Part Number Cage Code Manufacturer
TS125AP 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-229-1038

Technical Data | NSN 6625-00-229-1038

Characteristic Specifications
INPUT FREQUENCY RANGE 2.400 TO 3.335 GIGAHERTZ
RADIO FREQUENCY INPUT POWER RATING 2.0 MILLIWATTS NOMINAL
MEASUREMENT UNIT AVERAGE POWER
SCALE UNIT OF MEASURE INSCRIPTION MILLIWATTS AND DECIBELS
SCALE DIRECTION AND RANGE 0.TO 2 AND M10 TO P30 CLOCKWISE
INTERNAL BATTERY ACCOMMODATION INCLUDED
INCLOSURE FEATURE SINGLE ITEM W/CARRYING CASE
MATERIAL AND LOCATION ALUMINUM CARRYING CASE
LENGTH 10.000 INCHES NOMINAL
HEIGHT 5.313 INCHES NOMINAL
WIDTH 7.875 INCHES NOMINAL
ACCESSORY COMPONENT QUANTITY 1 AND 1 AND 1 AND 1
ACCESSORY CONTROLLING AGENCY JCENS
FURNISHED ITEMS ANTENNA,ATTENUATOR,ATTENUATOR,COR D
ACCESSORY IDENTIFYING NUMBER AT-67/AP TYPE NO. AND CN-43/UP TYPE NO. AND CN-43/UP TYPE NO. AND CG-171/AP TYPE NO.
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME POWER METER
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER TS-125/AP
NONDEFINITIVE SPEC/STD DATA TS-125/AP TYPE
III END ITEM IDENTIFICATION TYPE NO. AN/MPM-2,AN/MPM-5 AND AN/MPM-7

Restrictions/Controls & Freight Information | NSN 6625-00-229-1038

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable