Product Details | RADIO TEST SET

6625-00-240-1461 A test set primarily designed for use in making examinations of radio equipment. See also TEST SET, ELECTRON TUBE; MULTIMETER; OSCILLOSCOPE; GENERATOR, SIGNAL; and TEST SET, AMPLIFIER.

Part Alternates: AN/ARM-1, ANARM1, 6625-00-240-1461, 00-240-1461, 6625002401461, 002401461

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1963 00-240-1461

Cross Reference | NSN 6625-00-240-1461

Part Number Cage Code Manufacturer
AN/ARM-1 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-240-1461

Technical Data | NSN 6625-00-240-1461

Characteristic Specifications
TEST TYPE FOR WHICH DESIGNED ALIGNMENT OF FREQUENCY,MEASUREMENT OF VOLTAGE AND CURRENT
OPERATING TEST CAPABILITY TEST UNIT,0 TO 100 CALIBRATION,8 POSITION SELECTOR SWITCH MARKED /OSC/ 1,2,3,4,REC 4 TRANS A PLUS,B PLUS,RANGE 0 TO 50 MICROAMPERE,MOVEMENT PORM 2 PCT ACCURACY,DYNAMOTOR UNIT,INPUT 8 AMPERES AT 28V DC,OUTPUT 325 MA AT 400V DC,DYNAMOTOR UNIT,INPUT 2 AMPERES AT 28V DC,OUTPUT 125 MA AT 200V DC
DC VOLTAGE RATING 28.0 VOLTS NOMINAL
INTERNAL BATTERY ACCOMMODATION NOT INCLUDED
INCLOSURE FEATURE SINGLE ITEM W/CARRYING CASE
MATERIAL AND LOCATION ALUMINUM CARRYING CASE
HEIGHT 9.430 INCHES NOMINAL
LENGTH 17.500 INCHES NOMINAL
WIDTH 15.200 INCHES NOMINAL
MAJOR COMPONENTS CHEST,CONTROL BOX; DYNAMOTOR UNIT; DYNAMOTOR UNIT; JUNCTION BOX; TEST UNIT
ACCESSORY COMPONENT QUANTITY 1 AND 1 AND 1 AND 1 AND 1 AND 1
ACCESSORY CONTROLLING AGENCY JCENS
ACCESSORY IDENTIFYING NUMBER CY-146/ARM-1 TYPE NO. AND C118/ARC-3 TYPE NO.
MANUFACTURERS CODE 80058
DESIGN CONTROL REFERENCE AN/ARM-1

Restrictions/Controls & Freight Information | NSN 6625-00-240-1461

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 653 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code Q unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6625-00-240-1461

Category Code Description
Cognizance Codes9VNavy-owned stocks of material managed by the Air Force within the San Antonio Air Logistics Center
Naval Inventory Control Point, Mechanicsburg
Source of SupplyFPZSan Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each