Product Details | RADIO FREQUENCY POWER TEST SET

6625-00-242-5167 A test set primarily designed for use in making examinations of the power output of radio frequency oscillators and radio and radar transmitters. See also TEST SET, ELECTRICAL POWER; and WATTMETER.20211900057Specialized Test and Handling Equipment, Nuclear Ordnance66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: TS118AP, 6625-00-242-5167, 00-242-5167, 6625002425167, 002425167

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 01 JAN 1961 00-242-5167

Cross Reference | NSN 6625-00-242-5167

Part Number Cage Code Manufacturer
TS118AP 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6625-00-242-5167

Technical Data | NSN 6625-00-242-5167

Characteristic Specifications
INPUT FREQUENCY RANGE 20.000 TO 1000.000 MEGAHERTZ
RADIO FREQUENCY INPUT POWER RATING 5.0 WATTS MINIMUM AND 500.0 WATTS MAXIMUM
INPUT IMPEDANCE RATING 50.0 OHMS NOMINAL
MEASUREMENT UNIT AVERAGE POWER
SCALE DIRECTION AND RANGE 0 TO 1 CLOCKWISE
AC VOLTAGE RATING 115.0 VOLTS NOMINAL
FREQUENCY RATING 60.0 HERTZ NOMINAL
PHASE SINGLE
INCLOSURE FEATURE SINGLE ITEM W/CARRYING CASE
MATERIAL AND LOCATION WOOD CARRYING CASE
LENGTH 31.000 INCHES NOMINAL
HEIGHT 14.000 INCHES NOMINAL
WIDTH 12.500 INCHES NOMINAL
SPECIAL FEATURES SUPPLIED W/CONVERSION CHARTS TO CONVERT METER READINGS TO WATTS
III PRECIOUS MATERIAL SILVER
MANUFACTURERS CODE 80058
DESIGN CONTROL REFERENCE TS118AP

Restrictions/Controls & Freight Information | NSN 6625-00-242-5167

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:SItem contains silver
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating J 100.2
Water commodity Code 738 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Q Extremely fragile items including delicate instruments.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 6625-00-242-5167

Category Code Description
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeRHTG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC)
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilitySAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes7ZGeneral purpose electronic test equipment to support various Naval Systems Commands equipment/programs.
Naval Inventory Control Point, Mechanicsburg
Special Material IDTEGeneral purpose electronic test equipment
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityHDepot Level Reparable
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each